Adjustable collimation for dark-field proton radiography contrast enhancement
Review of Scientific Instruments · 01.05.2026 · 97 (5)
DOI: 10.1063/5.0312238 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 15.05.2026. Verfasst von J L Schmidt und 9 weiteren Autor:innen. Beteiligte Einrichtung: Los Alamos National Laboratory, Bikini Atoll Rd., Los Alamos, New Mexico 87545, USA. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Los Alamos National Laboratory.
Abstract (Originalsprache)
A dark-field imaging condition established through pre- and post-object beam collimation has been tested for a variety of different settings at the proton radiography facility (pRad) at Los Alamos National Laboratory. This technique facilitates imaging of thin samples and materials with small areal density changes with 800 MeV protons that would otherwise appear nearly transparent for high energy protons. In the configuration that was examined, the pre-object (upstream) collimator is utilized to remove protons with large scattering angles prior to the target object. The post-object collimation entails a combination of a conventional collimator, which eliminates protons with large scattering angles after target interaction, and an inverse collimator. The inverse collimator removes unscattered protons traveling on the beam axis and those with smaller scattering angles up to a desired angle. This establishes a dark-field condition by permitting solely protons that exhibit scattering angles from target interaction within a designated range to contribute to the image. This study explores the potential of combining different sized collimators for pre- and post-object collimation. The objective is to optimize contrast for a range of samples with minimal areal density variations. A series of dark-field conditions are explored employing a remote-controlled collimator wheel and the contrast-to-noise ratio, spatial resolution, and proton transmission are compared for those combinations. It is found that the contrast-to-noise ratio can be substantially enhanced for thin samples and low areal density objects, thereby facilitating capturing high-contrast images of objects that were previously invisible to high energy protons.
Autor:innen und Institutionen
- Los Alamos National Laboratory, Bikini Atoll Rd., Los Alamos, New Mexico 87545, USA.
ORCID-Profile: J L Schmidt, J C Allison, D Cardon, M A Espy, M S Freeman, W Z Meijer, F E Merrill, C L Morris, L P Neukirch, Z Tang
Förderung
- Los Alamos National Laboratory
Zitieren
APA
Schmidt, J. L., Allison, J. C., Cardon, D., Espy, M. A., Freeman, M. S., Meijer, W. Z., Merrill, F. E., Morris, C. L., Neukirch, L. P., & Tang, Z. (2026). Adjustable collimation for dark-field proton radiography contrast enhancement. Review of Scientific Instruments, 97(5). https://doi.org/10.1063/5.0312238
Vancouver
Schmidt JL, Allison JC, Cardon D, Espy MA, Freeman MS, Meijer WZ, et al. Adjustable collimation for dark-field proton radiography contrast enhancement. Review of Scientific Instruments. 2026;97(5). doi:10.1063/5.0312238
BibTeX
@article{Schmidt2026,
author = {Schmidt, J L and Allison, J C and Cardon, D and Espy, M A and Freeman, M S and Meijer, W Z and Merrill, F E and Morris, C L and Neukirch, L P and Tang, Z},
title = {Adjustable collimation for dark-field proton radiography contrast enhancement},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {5},
doi = {10.1063/5.0312238}
}
EUVIMED