Design and numerical simulation of a high-throughput dielectrophoresis microfluidic chip for continuous capture of active circulating tumor cells
AIP Advances · 01.04.2026 · 16 (4)
DOI: 10.1063/5.0311481 ↗Kurz gefasst
Fachartikel in der Zeitschrift AIP Advances, online erschienen am 29.04.2026. Verfasst von Yipei Wang und 4 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Henan Provincial Science and Technology Research Project.
Abstract (Originalsprache)
Circulating tumor cells (CTCs) are critical biomarkers for cancer liquid biopsy. Efficient and non-destructive separation of CTCs places high demands on the throughput and electric field control capabilities of dielectrophoresis (DEP) microfluidic chips. However, most existing DEP technologies remain limited to processing throughputs on the order of μl/h. To enhance chip performance, a Box–Behnken response surface design is employed to optimize key structural parameters, including electrode angle, electrode spacing, and channel height. Numerical simulations are conducted to systematically evaluate the effects of these parameters on the electric field distribution, flow rate, and cell capture efficiency. The results demonstrate that, under an applied electric field below the cell electroporation threshold, the optimal chip configuration consists of an electrode angle of 90°, an electrode spacing of 240 μm, and a channel height of 100 μm, ensuring effective preservation of cell integrity and viability. Under these conditions, an alternating current voltage of 6.62 Vpp enables a capture efficiency of 98.6% for MDA-MB-231 cells at a maximum flow rate of 2.16 ml/h. This study provides theoretical support for the design of high-throughput DEP microfluidic chips for tumor cell capture in clinical applications.
Förderung
- Henan Provincial Science and Technology Research Project
Zitieren
APA
Wang, Y., Hu, Z., Ou, C., Li, J., & Zu, X. (2026). Design and numerical simulation of a high-throughput dielectrophoresis microfluidic chip for continuous capture of active circulating tumor cells. AIP Advances, 16(4). https://doi.org/10.1063/5.0311481
Vancouver
Wang Y, Hu Z, Ou C, Li J, Zu X. Design and numerical simulation of a high-throughput dielectrophoresis microfluidic chip for continuous capture of active circulating tumor cells. AIP Advances. 2026;16(4). doi:10.1063/5.0311481
BibTeX
@article{Wang2026,
author = {Wang, Yipei and Hu, Zhigang and Ou, Cuisi and Li, Jinye and Zu, Xiangyang},
title = {Design and numerical simulation of a high-throughput dielectrophoresis microfluidic chip for continuous capture of active circulating tumor cells},
journal = {AIP Advances},
year = {2026},
volume = {16},
number = {4},
doi = {10.1063/5.0311481}
}
EUVIMED