Electrical resistivity of solid and liquid iron at high pressure in large-volume presses: A critical comparison between powder-compacted and solid wire samples
Review of Scientific Instruments · 01.03.2026 · 97 (3)
DOI: 10.1063/5.0310552 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 04.03.2026. Verfasst von Wenjun Yong und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Earth Sciences, University of Western Ontario, London, Ontario N6A 3K7, Canada. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 80 Literaturangaben. Gefördert von: Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
An accurate measurement of electrical resistivity of iron (Fe) and Fe-alloy systems at high temperatures and high pressures is essential for understanding the dynamics inside the metallic cores of planetary bodies. Many experimental studies have been carried out on the electrical resistivity of Fe and Fe-alloy compositions using both powder samples and wire samples with different experimental designs, and discrepancies in the measured values still persist. In this study, we evaluated multiple experimental designs using the four-wire method with Fe powder samples to assess the influence of sample geometry, melting, and contact materials on measured resistivity values in a large-volume multi-anvil press. Three configurations with varying sample diameters and geometrical constraints were tested at 5 GPa and beyond the melting temperature of Fe, revealing significant uncertainties due to deformation, especially in the molten state. These results indicate that electrical resistivity measurements with powder samples should be taken as the upper bound unless sample geometry is well preserved. Further experiments examined the effect of disk materials (Pt, W, and Re), with results indicating that higher resistivity materials, such as Re, may introduce larger discrepancies in measured values. With a geometric correction derived from previous room-temperature resistivity data, the agreement of resistivity values between wire and powder samples improves significantly. A two-step approach was then suggested for future experiments with powder samples to reduce uncertainties in resistivity measurements.
Autor:innen und Institutionen
- Department of Earth Sciences, University of Western Ontario, London, Ontario N6A 3K7, Canada.
ORCID-Profile: Wenjun Yong, E M Lenhart, Richard A Secco
Förderung
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Yong, W., Lenhart, E. M., & Secco, R. A. (2026). Electrical resistivity of solid and liquid iron at high pressure in large-volume presses: A critical comparison between powder-compacted and solid wire samples. Review of Scientific Instruments, 97(3). https://doi.org/10.1063/5.0310552
Vancouver
Yong W, Lenhart EM, Secco RA. Electrical resistivity of solid and liquid iron at high pressure in large-volume presses: A critical comparison between powder-compacted and solid wire samples. Review of Scientific Instruments. 2026;97(3). doi:10.1063/5.0310552
BibTeX
@article{Yong2026,
author = {Yong, Wenjun and Lenhart, E M and Secco, Richard A},
title = {Electrical resistivity of solid and liquid iron at high pressure in large-volume presses: A critical comparison between powder-compacted and solid wire samples},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {3},
doi = {10.1063/5.0310552}
}
EUVIMED