EUVIMEDEUVIMED entdecken
Crossref

Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers

Xuan Wang iD, Yu Wang iD, Jiajun Yuan iD, Changqing Feng iD, Wencong Wang, Junhai Zhang, Yufeng Shi iD, Shubin Liu iD

Review of Scientific Instruments · 01.03.2026 · 97 (3)

DOI: 10.1063/5.0310496 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 19.03.2026. Verfasst von Xuan Wang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China. Die Arbeit nennt 33 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-sensitivity and wide-bandwidth magnetometers are crucial for both terrestrial and space-based geophysical applications. In this work, we present an electronics design tailored for a helium optically pumped magnetometer (He-OPM) operating under ambient geomagnetic field conditions. The proposed design features low noise and fast response, which are critical for achieving high bandwidth and high sensitivity in He-OPMs. In addition, a phase compensation method is introduced to reduce phase errors introduced by the signal transmission path, including electronic delays, thereby improving measurement accuracy. The system performance is evaluated in a laboratory environment using a frequency-stabilized laser and effective magnetic shielding. Experimental results demonstrate that the influence of the electronics on measurement accuracy is below 40 pT per 1 μT, and the system achieves a bandwidth of 650 Hz. Under an applied magnetic field of ∼0.65 μT, the He-OPM achieves a sensitivity of 620fT/Hz@1Hz in closed-loop operation.

Autor:innen und Institutionen

  • Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.
  • Shandong Aerospace Electro-technology Institute, Yantai 264670, China.

ORCID-Profile: Xuan Wang, Yu Wang, Jiajun Yuan, Changqing Feng, Yufeng Shi, Shubin Liu

Zitieren

APA

Wang, X., Wang, Y., Yuan, J., Feng, C., Wang, W., Zhang, J., Shi, Y., & Liu, S. (2026). Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers. Review of Scientific Instruments, 97(3). https://doi.org/10.1063/5.0310496

Vancouver

Wang X, Wang Y, Yuan J, Feng C, Wang W, Zhang J, et al. Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers. Review of Scientific Instruments. 2026;97(3). doi:10.1063/5.0310496

BibTeX
@article{Wang2026,
  author = {Wang, Xuan and Wang, Yu and Yuan, Jiajun and Feng, Changqing and Wang, Wencong and Zhang, Junhai and Shi, Yufeng and Liu, Shubin},
  title = {Design of low-noise, fast-response electronics for high-performance helium optically pumped magnetometers},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {3},
  doi = {10.1063/5.0310496}
}