Environmental chambers for thin film characterization by grazing incidence x-ray scattering and broadband dielectric spectroscopy
Review of Scientific Instruments · 01.04.2026 · 97 (4)
DOI: 10.1063/5.0309613 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 14.04.2026. Verfasst von Benjamin T Ferko und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 64 Literaturangaben. Gefördert von: Division of Materials Research, Baden-Württemberg Stiftung, Deutsche Forschungsgemeinschaft.
Abstract (Originalsprache)
While x-ray scattering and broadband dielectric spectroscopy (BDS) experiments are routinely performed in vacuum and under controlled humidity on bulk samples, in situ measurements of thin films in non-aqueous solvent vapor environments introduce additional requirements. Two controlled environmental chambers for performing grazing incidence x-ray scattering and BDS address this critical need for studying thin films in either aqueous or organic atmospheres. Both chambers enable temperature-controlled measurements under ambient conditions, flowing gas or solvent vapor, or partial pressures generated by solvent reservoirs. In situ control of temperature is achieved by attaching to an external temperature controller. To facilitate grazing incidence small- and wide-angle x-ray scattering and x-ray reflectivity, the environmental chamber for grazing incidence x-ray scattering has exit angles of 2θ = 38° and 51° in the horizontal and vertical directions, respectively. Low x-ray attenuation (∼ 10%) is achieved by using Kapton windows, and the chamber is sealed to enable use in evacuated x-ray scattering systems such as the Xenocs Xeuss 2.0. The broadband dielectric spectroscopy environmental chamber measures dipole dynamics and ionic conductivities of materials on interdigitated electrodes. Cord grip feedthroughs eliminate additional capacitance from the sample chamber and make the environmental chamber broadly compatible with electrochemical impedance spectrometers. The utility of these chambers is demonstrated on three polymeric systems with various film thicknesses, morphologies, and solvents.
Autor:innen und Institutionen
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
- Department of Chemistry, University of Konstanz, Konstanz 78464, Germany.
ORCID-Profile: Benjamin T Ferko, Jack E Granite, Viola A Burlein, Stefan Mecking, Chinedum O Osuji, Karen I Winey
Förderung
- Division of Materials Research
- Baden-Württemberg Stiftung
- Deutsche Forschungsgemeinschaft
Zitieren
APA
Ferko, B. T., Granite, J. E., Burlein, V. A., Mecking, S., Osuji, C. O., & Winey, K. I. (2026). Environmental chambers for thin film characterization by grazing incidence x-ray scattering and broadband dielectric spectroscopy. Review of Scientific Instruments, 97(4). https://doi.org/10.1063/5.0309613
Vancouver
Ferko BT, Granite JE, Burlein VA, Mecking S, Osuji CO, Winey KI. Environmental chambers for thin film characterization by grazing incidence x-ray scattering and broadband dielectric spectroscopy. Review of Scientific Instruments. 2026;97(4). doi:10.1063/5.0309613
BibTeX
@article{Ferko2026,
author = {Ferko, Benjamin T and Granite, Jack E and Burlein, Viola A and Mecking, Stefan and Osuji, Chinedum O and Winey, Karen I},
title = {Environmental chambers for thin film characterization by grazing incidence x-ray scattering and broadband dielectric spectroscopy},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {4},
doi = {10.1063/5.0309613}
}
EUVIMED