Imaging efficiency optimization for x-ray fluorescence computed tomography based on Thomson scattering x-ray sources

Shengyuan Liu, Jichang Zhou, Yihong Zhang, Zhijun Chi

Journal of Applied Physics · 28.03.2026 · 139 (12)

DOI: 10.1063/5.0307937 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Physics, online erschienen am 24.03.2026. Verfasst von Shengyuan Liu und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

X-ray fluorescence computed tomography (XFCT) based on Thomson scattering x-ray sources is a novel molecular imaging technique applicable in both laboratory and clinical settings. However, its practical development is limited by relatively low imaging efficiency. To address this challenge, this study presents a dual approach that simultaneously optimizes the incident x-ray energy to maximize fluorescence yield and designs a three-pinhole collimator to enhance detection sensitivity. For the element gold (Au) widely used in XFCT imaging, the optimal incident x-ray energy was determined to be 82.6 keV for a Thomson scattering x-ray source with a root mean square bandwidth of 1%. Using contrast agents containing gold solutions with Au concentrations ranging from 0.1 to 4.0 wt. %, the performance of the designed imaging system was evaluated by Monte Carlo simulations. Compared to the conventional single-pinhole collimator, the three-pinhole design provides an approximately 2.5-fold enhancement in sensitivity and lowers the detection limit for gold solution from 0.183 to 0.161 wt. %. By increasing the incident x-ray energy to 100 keV, the scatter background was significantly reduced; however, lower contrast-to-noise ratios were observed across all gold solution concentrations, owing to the reduction of fluorescence yield at elevated x-ray energies. For the designed imaging system, a spatial resolution of approximately 0.7 mm can be achieved. Using this system, a complete XFCT scan can be completed in approximately 24 s using a Thomson scattering x-ray source with a photon yield of 1013 photons/s, without inducing pulse pileup effects; meanwhile, gold solutions with a concentration as low as 0.2 wt. % can be clearly resolved at a radiation dose of 2 Gy.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Liu, S., Zhou, J., Zhang, Y., & Chi, Z. (2026). Imaging efficiency optimization for x-ray fluorescence computed tomography based on Thomson scattering x-ray sources. Journal of Applied Physics, 139(12). https://doi.org/10.1063/5.0307937

Vancouver

Liu S, Zhou J, Zhang Y, Chi Z. Imaging efficiency optimization for x-ray fluorescence computed tomography based on Thomson scattering x-ray sources. Journal of Applied Physics. 2026;139(12). doi:10.1063/5.0307937

BibTeX
@article{Liu2026,
  author = {Liu, Shengyuan and Zhou, Jichang and Zhang, Yihong and Chi, Zhijun},
  title = {Imaging efficiency optimization for x-ray fluorescence computed tomography based on Thomson scattering x-ray sources},
  journal = {Journal of Applied Physics},
  year = {2026},
  volume = {139},
  number = {12},
  doi = {10.1063/5.0307937}
}
Kostenlos starten →