Wake control and power optimization of a two-turbine array using Taguchi method: Multi-parameter analysis of spacing, yaw angle, and hub height difference
Physics of Fluids · 01.01.2026 · 38 (1)
DOI: 10.1063/5.0305458 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 05.01.2026. Verfasst von Lihua Mi und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, A Project Supported by Science Research Fund of Zhejiang Provincial Education Department.
Abstract (Originalsprache)
It is crucial to maximize the power output of wind farms to enhance the efficiency of utilizing wind energy. Turbine operational parameters have a significant impact on this. Nine Taguchi experiments are conducted, with each parameter having three levels: downstream spacing (3D, 5D, and 7D), yaw angle (10°, 20°, and 30°), and hub height difference (−0.2D, 0D, and 0.2D), where D is the turbine diameter. The total power output (Ptotal) under different combinations is measured. Range analysis and analysis of variance (ANOVA) are employed to rank the sensitivities of the parameters and identify the optimal configuration. Additionally, the velocity contour visualization helps reveal the underlying wake mechanisms that affect variations in power output. The results obtained show that downstream spacing (L) has the most significant influence on power output, accounting for 77.8% of the variance in the ANOVA. The yaw angle (β) follows, with a contribution of 16.0%, and then the hub height difference (Δh) with a contribution of 5.9%. Thus, the order of parameter importance is determined as L > β > Δh. The optimal parameter configuration is found to be L = 7D and β = 10°, which has been proven to result in a relatively high total power output. The velocity contour analysis verifies that this configuration reduces wake interference, optimizes redirection, and separates the wake from the downstream turbine's rotor plane, thereby enhancing performance. These findings provide valuable guidance for optimizing wind farm layout, emphasizing L as the primary control parameter, and suggest that adjustments to β and Δh can enhance the wake management and the energy capture efficiency.
Förderung
- National Natural Science Foundation of China
- A Project Supported by Science Research Fund of Zhejiang Provincial Education Department
Zitieren
APA
Mi, L., Han, Y., Zhou, P., Chen, H., Li, B., Liu, J., & Cai, C. S. (2026). Wake control and power optimization of a two-turbine array using Taguchi method: Multi-parameter analysis of spacing, yaw angle, and hub height difference. Physics of Fluids, 38(1). https://doi.org/10.1063/5.0305458
Vancouver
Mi L, Han Y, Zhou P, Chen H, Li B, Liu J, et al. Wake control and power optimization of a two-turbine array using Taguchi method: Multi-parameter analysis of spacing, yaw angle, and hub height difference. Physics of Fluids. 2026;38(1). doi:10.1063/5.0305458
BibTeX
@article{Mi2026,
author = {Mi, Lihua and Han, Yan and Zhou, Pinhan and Chen, Hui and Li, Bo and Liu, Jiankun and Cai, C. S.},
title = {Wake control and power optimization of a two-turbine array using Taguchi method: Multi-parameter analysis of spacing, yaw angle, and hub height difference},
journal = {Physics of Fluids},
year = {2026},
volume = {38},
number = {1},
doi = {10.1063/5.0305458}
}
EUVIMED