High-energy, narrow-linewidth, pulsed 1083 nm laser system for metastable helium lidar
Review of Scientific Instruments · 01.07.2026 · 97 (7)
DOI: 10.1063/5.0302018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 27.07.2026. Verfasst von Zhaofeng Wang und 15 weiteren Autor:innen. Beteiligte Einrichtung: Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026, People's …. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 67 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Quantum Science and Technology - National Science and Technology Major Project, B-type Strategic Priority Program of CAS.
Abstract (Originalsprache)
We present a high-energy, narrow-linewidth, pulsed 1083 nm laser source designed for ground-based metastable helium (He in the 23S state) fluorescence lidar systems to probe the thermosphere and lower exosphere. The system is pumped by a neodymium doped yttrium aluminum garnet (Nd:YAG) laser with a 532–1064 nm dual-wavelength output and consists of three home-made parts: (1) a second harmonic generation stage that produces a 532 nm pump laser from the residual 1064 nm output of Nd:YAG, (2) an injection-seeded optical parametric generation (OPG) stage employing two KTiOPO4 (KTP) crystals in series and a wavelength-stabilized continuous-wave seed laser, and (3) optical parametric amplification stages (A1 and A2) to amplify the signal and idler beams generated by the OPG stage. The constructed prototype system, operating at a repetition rate of 50 Hz, has achieved an output energy of ∼140 mJ/pulse with a typical pulse duration of 8 ns and a laser linewidth of less than 92 MHz. The output wavelength is continuously tunable between 1083 and 1084 nm, with a pulse-to-pulse frequency jitter of ∼±5 MHz, which is likely limited by the linewidth of the unlocked seed laser. By using a wave meter-based locking scheme for the seed laser wavelength, the central wavelength of the output 1083 nm pulses is stabilized with a long-term frequency jitter of about ±46 MHz. This work provides a technical solution for a high-energy 1083 nm laser for ground-based metastable helium lidars.
Autor:innen und Institutionen
- Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
- Hefei National Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
- CAS Key Laboratory of Geospace Environment, School of Earth and Space Sciences, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
- CAS Center for Excellence in Comparative Planetology, Anhui Mengcheng Geophysics National Observation and Research Station, University of Science and Technology of China, Hefei, Anhui 230026, People's Republic of China.
ORCID-Profile: Zhaofeng Wang, Jieqiong Gu, Ruocan Zhao, Zhenzhen Li, Chaomei Wu, Boxing Zhu, Jinru Cheng, Zhenwei Liu, Weilong Luo, Chong Wang, Xianghui Xue, Dongfeng Zhao
Förderung
- National Natural Science Foundation of China
- Quantum Science and Technology - National Science and Technology Major Project
- B-type Strategic Priority Program of CAS
Zitieren
APA
Wang, Z., Gu, J., Zhao, R., Li, Z., Wu, C., Zhou, H., Zhu, B., Cheng, J., Liu, Z., Liang, C., Chen, T., Luo, W., Wang, C., Xue, X., Chen, Y., & Zhao, D. (2026). High-energy, narrow-linewidth, pulsed 1083 nm laser system for metastable helium lidar. Review of Scientific Instruments, 97(7). https://doi.org/10.1063/5.0302018
Vancouver
Wang Z, Gu J, Zhao R, Li Z, Wu C, Zhou H, et al. High-energy, narrow-linewidth, pulsed 1083 nm laser system for metastable helium lidar. Review of Scientific Instruments. 2026;97(7). doi:10.1063/5.0302018
BibTeX
@article{Wang2026,
author = {Wang, Zhaofeng and Gu, Jieqiong and Zhao, Ruocan and Li, Zhenzhen and Wu, Chaomei and Zhou, Hang and Zhu, Boxing and Cheng, Jinru and Liu, Zhenwei and Liang, Chen and Chen, Tingdi and Luo, Weilong and Wang, Chong and Xue, Xianghui and Chen, Yang and Zhao, Dongfeng},
title = {High-energy, narrow-linewidth, pulsed 1083 nm laser system for metastable helium lidar},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {7},
doi = {10.1063/5.0302018}
}
EUVIMED