EUVIMEDEUVIMED entdecken
Crossref

High performance two-dimensional photon-counting imaging detector based on delay line anode

Yalong Zhang iD, Yongan Liu, Xianghui Yang, Zhe Liu, Lizhi Sheng

Review of Scientific Instruments · 01.03.2026 · 97 (3)

DOI: 10.1063/5.0299830 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 09.03.2026. Verfasst von Yalong Zhang und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Transients Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119…. Die Arbeit nennt 19 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Basic Research Program of Shaanxi Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A microchannel plate detector based on a direct-collection cross-delay-line (XDL) anode readout is proposed. By converting spatial information into temporal signals and processing them with a high-speed time-to-digital converter, the system achieves a balance between high spatial resolution and high counting rate. The article elaborates on the detector’s design principles, image encoding system, and signal processing workflow. Experimental evaluations were conducted on key performance metrics, including the XDL encoding system’s nonlinearity, timing accuracy, as well as the overall spatial resolution and maximum counting rate of the detector. Test results demonstrate that the detector exhibits a spatial resolution better than 70 μm, a maximum counting rate of 1 MHz, and excellent timing precision (single-channel accuracy <26 ps). The encoding system exhibits good linearity with differential nonlinearity and integral nonlinearity below 0.22 and 2.29 LSB (least significant bit). The system is suitable for applications requiring high spatiotemporal resolution, such as particle detection, beam diagnostics, ultraviolet astronomy, and radiation imaging. Future work will focus on upgrading the data transmission interface and optimizing the electronic design to further enhance system performance.

Autor:innen und Institutionen

  • State Key Laboratory of Transients Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
  • University of Chinese Academy of Sciences, Beijing 100049, China.

ORCID-Profile: Yalong Zhang

Förderung

  • National Natural Science Foundation of China
  • Natural Science Basic Research Program of Shaanxi Province

Zitieren

APA

Zhang, Y., Liu, Y., Yang, X., Liu, Z., & Sheng, L. (2026). High performance two-dimensional photon-counting imaging detector based on delay line anode. Review of Scientific Instruments, 97(3). https://doi.org/10.1063/5.0299830

Vancouver

Zhang Y, Liu Y, Yang X, Liu Z, Sheng L. High performance two-dimensional photon-counting imaging detector based on delay line anode. Review of Scientific Instruments. 2026;97(3). doi:10.1063/5.0299830

BibTeX
@article{Zhang2026,
  author = {Zhang, Yalong and Liu, Yongan and Yang, Xianghui and Liu, Zhe and Sheng, Lizhi},
  title = {High performance two-dimensional photon-counting imaging detector based on delay line anode},
  journal = {Review of Scientific Instruments},
  year = {2026},
  volume = {97},
  number = {3},
  doi = {10.1063/5.0299830}
}
Kostenlos starten →