EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Refractive index based detection of acetaminophen using a simple singlemode–multimode–singlemode fiber-optic sensor

Luis Carlos Rivera-Peralta, Yamil Alejandro Zúñiga-Avalos, René Fernando Domínguez-Cruz, Yadira Aracely Fuentes-Rubio, Diego Alustiza, Valeria Beatriz Arce, Marcos Mineo

Journal of Applied Physics · 21.12.2025 · 138 (23)

DOI: 10.1063/5.0295859 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Physics, online erschienen am 16.12.2025. Verfasst von Luis Carlos Rivera-Peralta und 6 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Autónoma de Tamaulipas.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents the design, fabrication, and experimental validation of a low-cost optical sensor based on refractive index variation for the detection of acetaminophen (commonly called paracetamol) in liquid solutions. The sensor uses a multimode interference effect under an architecture built with a singlemode–no-core multimode–singlemode fibers (SMF–NC-MMF–SMF or frequently known as SMS). Taking advantage of the self-imaging effect inherent to multimodal interference and the evanescent field interaction with the surrounding media, the sensor exhibits high sensitivity to refractive index changes induced by variations in analyte concentration. Test solutions were prepared from ground commercial tablets containing 85% of active pharmaceutical ingredients. Acetaminophen concentrations in hydroalcoholic solutions, ranging from 17.54 to 128.03 g/kg, were quantified. A progressive shift of the transmission peak toward longer wavelengths, correlated with increasing acetaminophen concentration, was observed when the NC-MMF segment was immersed in each solution. The device demonstrated a spectral sensitivity of 0.024 92 nm/(g/kg), with a linearity (R2 = 0.988), and an estimated limit of detection ∼8.2 g/kg. Additionally, a negative shift attributed to the thermo-optic coefficient of the medium was observed in thermal tests conducted from 20 to 40 °C. However, crystallization effects of acetaminophen are observed above 40 °C, which limits the useful monitoring range. Compared with other methods, the proposed SMS sensor achieves comparable performance through simple construction and without specialized coatings, positioning it as a promising alternative for real-time optical monitoring of pharmaceutical compounds in liquid media.

Förderung

  • Universidad Autónoma de Tamaulipas

Zitieren

APA

Rivera-Peralta, L. C., Zúñiga-Avalos, Y. A., Domínguez-Cruz, R. F., Fuentes-Rubio, Y. A., Alustiza, D., Arce, V. B., & Mineo, M. (2025). Refractive index based detection of acetaminophen using a simple singlemode–multimode–singlemode fiber-optic sensor. Journal of Applied Physics, 138(23). https://doi.org/10.1063/5.0295859

Vancouver

Rivera-Peralta LC, Zúñiga-Avalos YA, Domínguez-Cruz RF, Fuentes-Rubio YA, Alustiza D, Arce VB, et al. Refractive index based detection of acetaminophen using a simple singlemode–multimode–singlemode fiber-optic sensor. Journal of Applied Physics. 2025;138(23). doi:10.1063/5.0295859

BibTeX
@article{RiveraPeralta2025,
  author = {Rivera-Peralta, Luis Carlos and Zúñiga-Avalos, Yamil Alejandro and Domínguez-Cruz, René Fernando and Fuentes-Rubio, Yadira Aracely and Alustiza, Diego and Arce, Valeria Beatriz and Mineo, Marcos},
  title = {Refractive index based detection of acetaminophen using a simple singlemode–multimode–singlemode fiber-optic sensor},
  journal = {Journal of Applied Physics},
  year = {2025},
  volume = {138},
  number = {23},
  doi = {10.1063/5.0295859}
}
Kostenlos starten →