An approach for measuring the magnetic susceptibility of diamond using a tunnel magnetoresistance (TMR) sensor array
Review of Scientific Instruments · 01.04.2026 · 97 (4)
DOI: 10.1063/5.0293978 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 06.04.2026. Verfasst von Qiao Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Grain Information Processing and Control (Henan University of Technology), Ministry of Education, Zhengzhou 450000, China. Die Arbeit nennt 22 Literaturangaben. Gefördert von: Henan Provincial Science and Technology Research Project, Henan University of Technology.
Abstract (Originalsprache)
Low-frequency magnetic susceptibility is a critical parameter for evaluating the magnetic properties of diamonds and is closely related to their physical characteristics, such as compressive strength and thermal stability. To overcome the limitations of conventional susceptibility measurement methods, this study proposes a novel approach for quantifying diamond magnetic susceptibility using a tunnel magnetoresistance (TMR) sensor array. To address the ill-posed nature of image reconstruction and the limited accuracy of linear mapping, two key optimization strategies are introduced: (1) a sparse autoencoder-based reconstruction algorithm (SAE-EMT) that incorporates nonlinear prior constraints to enhance image reconstruction accuracy, and (2) a gradient-optimized mapping strategy that enables accurate conversion from relative susceptibility distributions to absolute susceptibility values. Experimental results demonstrate that the SAE-EMT algorithm outperforms conventional Tikhonov and Landweber methods in terms of image quality and robustness, maintaining high reconstruction accuracy even under noisy conditions. Moreover, the gradient-optimized mapping strategy reduces the relative error by 34% and improves the signal-to-noise ratio by 6 dB, while more accurately capturing susceptibility variations and reducing the gradient magnitude similarity deviation by 40%.
Autor:innen und Institutionen
- Key Laboratory of Grain Information Processing and Control (Henan University of Technology), Ministry of Education, Zhengzhou 450000, China.
- Henan Key Laboratory of Grain Photoelectric Detection and Control, Henan University of Technology, Zhengzhou 450000, China.
- College of Electrical Engineering, Henan University of Technology, Zhengzhou 450000, China.
- Center of Big Data and Computer Application Science and Education, Engineering Department, Huanghe University of Science and Technology, Zhengzhou 450000, China.
ORCID-Profile: Qiao Wang, Haofu Zhang, Yaping Shi, Qunfeng Niu, Li Wang
Förderung
- Henan Provincial Science and Technology Research Project
- Henan University of Technology
Zitieren
APA
Wang, Q., Zhang, H., Shi, Y., Niu, Q., & Wang, L. (2026). An approach for measuring the magnetic susceptibility of diamond using a tunnel magnetoresistance (TMR) sensor array. Review of Scientific Instruments, 97(4). https://doi.org/10.1063/5.0293978
Vancouver
Wang Q, Zhang H, Shi Y, Niu Q, Wang L. An approach for measuring the magnetic susceptibility of diamond using a tunnel magnetoresistance (TMR) sensor array. Review of Scientific Instruments. 2026;97(4). doi:10.1063/5.0293978
BibTeX
@article{Wang2026,
author = {Wang, Qiao and Zhang, Haofu and Shi, Yaping and Niu, Qunfeng and Wang, Li},
title = {An approach for measuring the magnetic susceptibility of diamond using a tunnel magnetoresistance (TMR) sensor array},
journal = {Review of Scientific Instruments},
year = {2026},
volume = {97},
number = {4},
doi = {10.1063/5.0293978}
}
EUVIMED