EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Hydrodynamic tuning of nitrogen plasma in a fast pulsed channel for liquid activation stability

Saif B. Mohammed, H. Ahmet Yıldırım

AIP Advances · 01.09.2025 · 15 (9)

DOI: 10.1063/5.0290873 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIP Advances, online erschienen am 24.09.2025. Verfasst von Saif B. Mohammed und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates the hydrodynamic and physicochemical behavior of a nitrogen Fast Pulsed Discharge plasma system for treating deionized water (DIW) and 0.75% hyaluronic acid gel (HAG). The discharge channel consists of hemispherical electrodes (2 mm gap, 26 cm length) powered by a locally assembled high-voltage source (≤15 kV), with nitrogen injected centrally and distributed along the plasma channel. Flow rates from 1 to 15 L/min were examined, and key physical parameters—Mach number, Reynolds number, dynamic pressure, and residence time—were calculated. Plasma irradiation was applied to the liquids for 5, 10, 15, and 20 min, with both theoretical and experimental results confirming that 5 L/min represents the optimal condition, yielding subsonic flow (Mach ≈ 0.025), a transitional regime (Re ≈ 1900), and a stable plasma glow. Post-treatment monitoring over four days revealed that HAG exhibited superior physicochemical stability compared to DIW. Measurements of pH, ORP, and EC showed that DIW underwent pronounced fluctuations with only partial recovery, whereas HAG maintained nearly stable values, reflecting its enhanced buffering and activation capacity. In contrast, zeta potential was measured only at the 20-min irradiation point, where both HAG and DIW displayed significant surface charge modification, providing further evidence of plasma-induced interfacial changes. These findings demonstrate that a 5 L/min nitrogen feed ensures optimal plasma uniformity and liquid activation, supporting the development of plasma-activated media with improved storage capability for biomedical applications.

Zitieren

APA

Mohammed, S. B., & Yıldırım, H. A. (2025). Hydrodynamic tuning of nitrogen plasma in a fast pulsed channel for liquid activation stability. AIP Advances, 15(9). https://doi.org/10.1063/5.0290873

Vancouver

Mohammed SB, Yıldırım HA. Hydrodynamic tuning of nitrogen plasma in a fast pulsed channel for liquid activation stability. AIP Advances. 2025;15(9). doi:10.1063/5.0290873

BibTeX
@article{Mohammed2025,
  author = {Mohammed, Saif B. and Yıldırım, H. Ahmet},
  title = {Hydrodynamic tuning of nitrogen plasma in a fast pulsed channel for liquid activation stability},
  journal = {AIP Advances},
  year = {2025},
  volume = {15},
  number = {9},
  doi = {10.1063/5.0290873}
}
Kostenlos starten →