EUVIMEDEUVIMED entdecken
Crossref

Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens

A E Raymond iD, N Pelepchan, J Hassett, R Boni

Review of Scientific Instruments · 01.10.2025 · 96 (10)

DOI: 10.1063/5.0287750 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 15.10.2025. Verfasst von A E Raymond und 3 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: National Nuclear Security Administration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The BHx streak tube, under development at the Laboratory for Laser Energetics, incorporates a series of novel electron-optics elements to enable high fidelity measurements for high-energy-density physics experiments. The system is engineered to support a 25-mm active photocathode region compatible with sub-picosecond temporal resolution and with 70% internal photoelectron throughput. It exhibits negligible geometric distortion on a flat output screen, making it well suited for variety of measurements, such as ultrafast x-ray spectroscopy. This paper presents characterization data from a prototype unit tested with an ultraviolet laser in a static deflection (non-swept) mode and shows good agreement with the predictions from numerical modeling, including focusing performance and geometric distortion measurements. Key design elements have been demonstrated and de-risked, laying the foundation for dynamic deflection testing. The anticipated improvements in data fidelity are expected to impact the fields as diverse as inertial confinement fusion, laboratory astrophysics, and materials science.

Autor:innen und Institutionen

  • Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA.

ORCID-Profile: A E Raymond

Förderung

  • National Nuclear Security Administration

Zitieren

APA

Raymond, A. E., Pelepchan, N., Hassett, J., & Boni, R. (2025). Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens. Review of Scientific Instruments, 96(10). https://doi.org/10.1063/5.0287750

Vancouver

Raymond AE, Pelepchan N, Hassett J, Boni R. Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens. Review of Scientific Instruments. 2025;96(10). doi:10.1063/5.0287750

BibTeX
@article{Raymond2025,
  author = {Raymond, A E and Pelepchan, N and Hassett, J and Boni, R},
  title = {Static characterization of a highly optimized streak tube design incorporating a steering slot anode and an aberration-corrected Einzel lens},
  journal = {Review of Scientific Instruments},
  year = {2025},
  volume = {96},
  number = {10},
  doi = {10.1063/5.0287750}
}
Kostenlos starten →