Comparative performance analysis of single-phase transformerless grid-tied solar photovoltaic inverter topologies

Vijaychandra Joddumahanthi, Santi Behera

Journal of Renewable and Sustainable Energy · 01.05.2026 · 18 (3)

DOI: 10.1063/5.0287273 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Renewable and Sustainable Energy, online erschienen am 21.05.2026. Verfasst von Vijaychandra Joddumahanthi und 1 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, various configurations of single-phase (1-ϕ) transformerless grid-tied solar photovoltaic (PV) inverters are analyzed. In the past decades, 1-ϕ transformerless inverters have gained popularity in grid-tied PV system applications as they are cheaper to construct, less complicated, and have greater efficiency. But a serious drawback observed in the form of leakage current, which may result from a lack of galvanic separation between the PV panels and the electric grid. In this paper, a comparative study of different inverter topologies is done. In addition to this, common mode voltage, leakage current, and total harmonic distortion (THD) are studied. A parasitic capacitance-driven model is used for calculating leakage currents. A sinusoidal pulse width modulation strategy has been used to generate required switching pulses to the inverter, where a 50 Hz sinusoidal reference signal is compared with a 10 kHz triangular carrier signal. Simulation results indicate that the improved H6-IV inverter configuration shows superior performance over the rest of the inverters. The leakage current is reduced from 69.27 (Heric) to 45.79 mA (improved H6-IV), indicating an approximate reduction in 33%, besides the THD value reduced to 1.78% from 2.7%, and furthermore, the efficiency to be 98.2% in the case of improved H6-IV inverter. This is achieved by the inclusion of an anti-parallel diode arrangement in the inverter topology, which effectively clamps the common mode voltage to exactly half of the DC-link voltage and thus alleviates leakage currents. The study of the inverter configurations is carried out by using MATLAB/Simulink software.

Zitieren

APA

Joddumahanthi, V., & Behera, S. (2026). Comparative performance analysis of single-phase transformerless grid-tied solar photovoltaic inverter topologies. Journal of Renewable and Sustainable Energy, 18(3). https://doi.org/10.1063/5.0287273

Vancouver

Joddumahanthi V, Behera S. Comparative performance analysis of single-phase transformerless grid-tied solar photovoltaic inverter topologies. Journal of Renewable and Sustainable Energy. 2026;18(3). doi:10.1063/5.0287273

BibTeX
@article{Joddumahanthi2026,
  author = {Joddumahanthi, Vijaychandra and Behera, Santi},
  title = {Comparative performance analysis of single-phase transformerless grid-tied solar photovoltaic inverter topologies},
  journal = {Journal of Renewable and Sustainable Energy},