EUVIMEDEUVIMED entdecken
Crossref

Effects of coiling index and vessel diameter on umbilical artery flow: A computational fluid dynamics study

Xue Song, Mingrui Li, Jingying Wang, Shiyue Zhang, Chunhian Lee

Physics of Fluids · 01.08.2025 · 37 (8)

DOI: 10.1063/5.0285503 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 26.08.2025. Verfasst von Xue Song und 4 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 42 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The hemodynamics of the umbilical artery (UA) are critical to fetal development, with the umbilical coiling index (UCI) and vessel diameter identified as key geometric factors influencing blood flow patterns and related pregnancy outcomes. In this study, a three-dimensional computational fluid dynamics (CFD) model based on the Carreau non-Newtonian viscosity of blood is applied, and validated by particle image velocimetry experiments, to investigate the independent and combined effects of UCI and vessel diameter on UA hemodynamics. The results reveal that the UCI increase promotes the uniformity of velocity distribution, significantly enhances inlet pressure (up to twice that of a normal UA) and peak wall shear stress (WSS), with the extension of high Q-criterion region. It potentially induces endothelial stress and impairs placental perfusion, thus increasing the risk of fetal growth restriction (FGR). However, the UCI decrease can accelerate blood flow, also destabilizing flow and possibly disrupting placental function. The vessel diameter reduction has a pronounced impact that remarkably increases flow velocity, pressure, high Q-criterion region size, and WSS (up to fivefold), which may exacerbate flow irregularities and elevate the risk of FGR. Enlarged diameters reduce velocity and may raise blood viscosity, with limited effects on pressure and WSS, potentially increasing the risk of thrombosis. When UCI and diameter vary simultaneously, the vessel diameter predominantly determines hemodynamic behavior, while the UCI only has a secondary influence. The secondary flow structures remain spatially consistent, showing robustness to geometric variations. This study quantitatively reveals how UCI and vessel diameter affect UA flow, offering insights into placental dysfunction and adverse outcomes.

Zitieren

APA

Song, X., Li, M., Wang, J., Zhang, S., & Lee, C. (2025). Effects of coiling index and vessel diameter on umbilical artery flow: A computational fluid dynamics study. Physics of Fluids, 37(8). https://doi.org/10.1063/5.0285503

Vancouver

Song X, Li M, Wang J, Zhang S, Lee C. Effects of coiling index and vessel diameter on umbilical artery flow: A computational fluid dynamics study. Physics of Fluids. 2025;37(8). doi:10.1063/5.0285503

BibTeX
@article{Song2025,
  author = {Song, Xue and Li, Mingrui and Wang, Jingying and Zhang, Shiyue and Lee, Chunhian},
  title = {Effects of coiling index and vessel diameter on umbilical artery flow: A computational fluid dynamics study},
  journal = {Physics of Fluids},
  year = {2025},
  volume = {37},
  number = {8},
  doi = {10.1063/5.0285503}
}
Kostenlos starten →