EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Ultra-high resolution tilt calibration and real-time compensation for cold atom gravimeters

Zhiye Song iD, Yaning Wang, Guangming Wang, Weijing Zhao, Lingxiao Zhu

Review of Scientific Instruments · 01.10.2025 · 96 (10)

DOI: 10.1063/5.0283458 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.10.2025. Verfasst von Zhiye Song und 4 weiteren Autor:innen. Beteiligte Einrichtung: College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The angular misalignment between two Raman beams is a critical source of error in gravity measurements using cold atom gravimeters. This paper presents the design and experimental validation of an integrated optical fiber module based on the principle of optical reversibility. The proposed module enables calibration of Raman beam polarization orthogonality and overlap angles while simultaneously providing real-time compensation for gravity measurement errors induced by Raman beam misalignment through continuous monitoring of the calibration signal. Experimental results demonstrate that the module achieves a Raman mirror tilt angle calibration accuracy of 1.6 arc sec, corresponding to a gravity acceleration calibration accuracy of 0.06 μGal. The implementation of this module enhances calibration efficiency, mitigates alignment-related disturbances, and improves the overall stability of atomic gravimeter measurements. Its versatility makes it suitable for deployment in both high-accuracy stationary laboratory experiments and dynamic field applications, advancing the practical utility of cold atom gravimeters in geophysical and metrological research.

Autor:innen und Institutionen

  • College of Intelligence Science and Technology, National University of Defense Technology, Changsha 410073, China.
  • Interdisciplinary Center for Quantum Information, National University of Defense Technology, Changsha 410073, China.
  • Changsha Quantum Measurement Industry Technology Research Institute Co., Ltd, Changsha 410017, China.

ORCID-Profile: Zhiye Song

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Song, Z., Wang, Y., Wang, G., Zhao, W., & Zhu, L. (2025). Ultra-high resolution tilt calibration and real-time compensation for cold atom gravimeters. Review of Scientific Instruments, 96(10). https://doi.org/10.1063/5.0283458

Vancouver

Song Z, Wang Y, Wang G, Zhao W, Zhu L. Ultra-high resolution tilt calibration and real-time compensation for cold atom gravimeters. Review of Scientific Instruments. 2025;96(10). doi:10.1063/5.0283458

BibTeX
@article{Song2025,
  author = {Song, Zhiye and Wang, Yaning and Wang, Guangming and Zhao, Weijing and Zhu, Lingxiao},
  title = {Ultra-high resolution tilt calibration and real-time compensation for cold atom gravimeters},
  journal = {Review of Scientific Instruments},
  year = {2025},
  volume = {96},
  number = {10},
  doi = {10.1063/5.0283458}
}
Kostenlos starten →