Crosstalk reduction in optically pumped magnetometers arrays for biomagnetic measurement
Review of Scientific Instruments · 01.08.2025 · 96 (8)
DOI: 10.1063/5.0273491 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 26.08.2025. Verfasst von Tianbo Wu und 4 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Photonics and Communications, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijin…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Magnetoencephalography based on the compact OPM (Optically Pumped Magnetometer) array offers a series of advantages, such as low cost and wearability, and is gradually being used in brain science research and the diagnosis and treatment of brain diseases, such as epilepsy and dementia. As the distance between parametric resonance spin-exchange relaxation-free OPM sensors decreases, the array experiences increased crosstalk effect. We design a low-crosstalk coil to suppress magnetic field leakage, thereby reducing the impact of crosstalk. We compare the field leakage of the low-crosstalk coil and the Helmholtz-like coil and validate the performance of the coil using a 2 × 2 OPM array. The low-crosstalk coil demonstrates improved magnetic field suppression performance, and the noise floor of the OPM array reduces from ∼45 to 20 fT/Hz1/2.
Autor:innen und Institutionen
- State Key Laboratory of Photonics and Communications, School of Electronics, and Center for Quantum Information Technology, Peking University, Beijing 100871, China.
- MIIT Key Laboratory of Complex-field Intelligent Sensing, Advanced Research Institute of Multidisciplinary Science, Beijing Institute of Technology, Beijing 100081, China.
ORCID-Profile: Tianbo Wu, Wei Xiao, Xiang Peng, Teng Wu, Hong Guo
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Wu, T., Xiao, W., Peng, X., Wu, T., & Guo, H. (2025). Crosstalk reduction in optically pumped magnetometers arrays for biomagnetic measurement. Review of Scientific Instruments, 96(8). https://doi.org/10.1063/5.0273491
Vancouver
Wu T, Xiao W, Peng X, Wu T, Guo H. Crosstalk reduction in optically pumped magnetometers arrays for biomagnetic measurement. Review of Scientific Instruments. 2025;96(8). doi:10.1063/5.0273491
BibTeX
@article{Wu2025,
author = {Wu, Tianbo and Xiao, Wei and Peng, Xiang and Wu, Teng and Guo, Hong},
title = {Crosstalk reduction in optically pumped magnetometers arrays for biomagnetic measurement},
journal = {Review of Scientific Instruments},
year = {2025},
volume = {96},
number = {8},
doi = {10.1063/5.0273491}
}
EUVIMED