EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

G. F. Swadling, W. A. Farmer, H. Chen, N. Aybar, M. S. Rubery, M. B. Schneider, D. A. Liedahl, N. Lemos, E. Tubman, J. S. Ross, D. E. Hinkel, O. L. Landen und 10 weitere

Physics of Plasmas · 01.05.2025 · 32 (5)

DOI: 10.1063/5.0259922 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Plasmas, online erschienen am 16.05.2025. Verfasst von G. F. Swadling und 21 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 80 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Lawrence Livermore National Laboratory, National Nuclear Security Administration.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigated discrepancies between measured and simulated x-ray drive in Indirect-Drive Inertial Confinement Fusion (ID-ICF) hohlraums at the National Ignition Facility. Despite advances in radiation-hydrodynamic simulations, a consistent “drive deficit” remains. Experimentally measured ID-ICF capsule bang-times are systematically 400–700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allow us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure, and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data support the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2–4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

Förderung

  • Lawrence Livermore National Laboratory
  • National Nuclear Security Administration

Zitieren

APA

Swadling, G. F., Farmer, W. A., Chen, H., Aybar, N., Rubery, M. S., Schneider, M. B., Liedahl, D. A., Lemos, N., Tubman, E., Ross, J. S., Hinkel, D. E., Landen, O. L., Rosen, M. D., Rogers, S., Newman, K., Yanagisawa, D., Roskopf, N., Vonhof, S., Aghaian, L., …, & Kunimune, J. (2025). Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign. Physics of Plasmas, 32(5). https://doi.org/10.1063/5.0259922

Vancouver

Swadling GF, Farmer WA, Chen H, Aybar N, Rubery MS, Schneider MB, et al. Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign. Physics of Plasmas. 2025;32(5). doi:10.1063/5.0259922

BibTeX
@article{Swadling2025,
  author = {Swadling, G. F. and Farmer, W. A. and Chen, H. and Aybar, N. and Rubery, M. S. and Schneider, M. B. and Liedahl, D. A. and Lemos, N. and Tubman, E. and Ross, J. S. and Hinkel, D. E. and Landen, O. L. and Rosen, M. D. and Rogers, S. and Newman, K. and Yanagisawa, D. and Roskopf, N. and Vonhof, S. and Aghaian, L. and Mauldin, M. and Reichelt, B. L. and Kunimune, J.},
  title = {Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign},
  journal = {Physics of Plasmas},
  year = {2025},
  volume = {32},
  number = {5},
  doi = {10.1063/5.0259922}
}
Kostenlos starten →