Performance evaluation of a diamond quantum magnetometer for biomagnetic sensing: A phantom study
Applied Physics Letters · 12.05.2025 · 126 (19)
DOI: 10.1063/5.0254828 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 12.05.2025. Verfasst von Naota Sekiguchi und 12 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Ministry of Education, Culture, Sports, Science and Technology.
Abstract (Originalsprache)
We employ a dry-type phantom to evaluate the performance of a diamond quantum magnetometer with a high sensitivity of about 6 pT/Hz from the viewpoint of practical measurement in biomagnetic sensing. The dry phantom is supposed to represent an equivalent current dipole (ECD) generated by brain activity, emulating an encephalomagnetic field. The spatial resolution of the magnetometer is evaluated to be sufficiently higher than the length of the variation in the encephalomagnetic field distribution. The minimum detectable ECD moment is evaluated to be 0.2 nA m by averaging about 8000 measurements for a standoff distance of 2.4 mm from the ECD. We also discuss the feasibility of detecting an ECD in the measurement of an encephalomagnetic field in humans. We conclude that it is feasible to detect an encephalomagnetic field from a shallow cortex area such as the primary somatosensory cortex.
Förderung
- Ministry of Education, Culture, Sports, Science and Technology
Zitieren
APA
Sekiguchi, N., Kainuma, Y., Fushimi, M., Shinei, C., Miyakawa, M., Taniguchi, T., Teraji, T., Abe, H., Onoda, S., Ohshima, T., Hatano, M., Sekino, M., & Iwasaki, T. (2025). Performance evaluation of a diamond quantum magnetometer for biomagnetic sensing: A phantom study. Applied Physics Letters, 126(19). https://doi.org/10.1063/5.0254828
Vancouver
Sekiguchi N, Kainuma Y, Fushimi M, Shinei C, Miyakawa M, Taniguchi T, et al. Performance evaluation of a diamond quantum magnetometer for biomagnetic sensing: A phantom study. Applied Physics Letters. 2025;126(19). doi:10.1063/5.0254828
BibTeX
@article{Sekiguchi2025,
author = {Sekiguchi, Naota and Kainuma, Yuta and Fushimi, Motofumi and Shinei, Chikara and Miyakawa, Masashi and Taniguchi, Takashi and Teraji, Tokuyuki and Abe, Hiroshi and Onoda, Shinobu and Ohshima, Takeshi and Hatano, Mutsuko and Sekino, Masaki and Iwasaki, Takayuki},
title = {Performance evaluation of a diamond quantum magnetometer for biomagnetic sensing: A phantom study},
journal = {Applied Physics Letters},
year = {2025},
volume = {126},
number = {19},
doi = {10.1063/5.0254828}
}
EUVIMED