Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging
Review of Scientific Instruments · 01.04.2025 · 96 (4)
DOI: 10.1063/5.0253841 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 21.04.2025. Verfasst von Jessica Z Dixon und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, Georgia Institute of Technology, 950 Atlantic Drive, Atlanta, Georgia 30332, USA. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Microscopy. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Cancer Institute, U.S. Department of Energy.
Abstract (Originalsprache)
Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. We report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Chemistry and Biochemistry, Georgia Institute of Technology, 950 Atlantic Drive, Atlanta, Georgia 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology, 950 Atlantic Drive, Atlanta, Georgia 30332, USA.
ORCID-Profile: Jessica Z Dixon, Wei-Wen Chen, Haoyu Xu, Xavier Audier, Marcus T Cicerone
Förderung
- NCI NIH HHS
- National Cancer Institute
- U.S. Department of Energy
Zitieren
APA
Dixon, J. Z., Chen, W. W., Xu, H., Audier, X., & Cicerone, M. T. (2025). Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging. Review of Scientific Instruments, 96(4). https://doi.org/10.1063/5.0253841
Vancouver
Dixon JZ, Chen WW, Xu H, Audier X, Cicerone MT. Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging. Review of Scientific Instruments. 2025;96(4). doi:10.1063/5.0253841
BibTeX
@article{Dixon2025,
author = {Dixon, Jessica Z and Chen, Wei-Wen and Xu, Haoyu and Audier, Xavier and Cicerone, Marcus T},
title = {Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging},
journal = {Review of Scientific Instruments},
year = {2025},
volume = {96},
number = {4},
doi = {10.1063/5.0253841}
}
EUVIMED