Effective optimization of measurement accuracy of rotational viscometers based on the double cylindrical perturbation model
Review of Scientific Instruments · 01.05.2025 · 96 (5)
DOI: 10.1063/5.0251999 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 01.05.2025. Verfasst von Yue Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: College of Aerospace and Aviation, Xi'an Jiaotong University, Shaanxi 710049, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: National Natural Science Foundation of China-China Academy of General Technology Joint Fund for Basic Research.
Abstract (Originalsprache)
We introduce an optimized principle for measuring liquid viscosity based on the rotational method. This principle can be further utilized in an improved dynamic torque viscosity testing system to obtain a wide range of viscosities with high accuracy. Newton’s law of viscosity serves as the foundation for the traditional rotational viscosity measurement principle, which measures a liquid’s viscosity by measuring its resistance to a rotating cylinder. Throughout the studies, it was discovered that the liquid’s viscous interaction with the vessel’s top and bottom surfaces regularly produced extra torque that would have raised the measurement results. The instability and unpredictability of the measurement core device often affect the accuracy of the measurements. Hence, we improved the calculation method for traditional viscometer measurements and used a high-precision dynamic torque sensor to modify the fundamental measuring element. To ensure the precision and dependability of the results, the experimental apparatus was calibrated and tested using standard substances (H2O and NaCl). We found that the average error of the viscosity measurements was below 2.73% within the 0–60 rpm range, with a minimum detectable difference of 1 µPa·s. Furthermore, the experimental system further stores and analyzes the data using RS485 communication with a host computer.
Autor:innen und Institutionen
- College of Aerospace and Aviation, Xi'an Jiaotong University, Shaanxi 710049, China.
ORCID-Profile: Yue Li
Förderung
- National Natural Science Foundation of China-China Academy of General Technology Joint Fund for Basic Research
Zitieren
APA
Li, Y., Zou, Q., & Ma, L. (2025). Effective optimization of measurement accuracy of rotational viscometers based on the double cylindrical perturbation model. Review of Scientific Instruments, 96(5). https://doi.org/10.1063/5.0251999
Vancouver
Li Y, Zou Q, Ma L. Effective optimization of measurement accuracy of rotational viscometers based on the double cylindrical perturbation model. Review of Scientific Instruments. 2025;96(5). doi:10.1063/5.0251999
BibTeX
@article{Li2025,
author = {Li, Yue and Zou, Qiangsheng and Ma, Lifeng},
title = {Effective optimization of measurement accuracy of rotational viscometers based on the double cylindrical perturbation model},
journal = {Review of Scientific Instruments},
year = {2025},
volume = {96},
number = {5},
doi = {10.1063/5.0251999}
}
EUVIMED