EUVIMEDEUVIMED entdecken
Crossref

Ultrasensitive probing of nematic order parameter via weak measurement

Changyou Wang, Yunhan Wang, Yurong Liu, Tong Li, Lan Luo, Sijie Zhang, Zhiyou Zhang

Applied Physics Letters · 20.01.2025 · 126 (3)

DOI: 10.1063/5.0250113 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 21.01.2025. Verfasst von Changyou Wang und 6 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Undergraduate Innovation and Entrepreneurship Training Program, Science and Technology Support Program of Sichuan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Nematic order parameter S is one of the most crucial material parameters of the nematic phase, which governs all of the material's anisotropic properties. The enhancement of its measurement precision has always been a great concern. In this Letter, a weak measurement scheme with a modified shift pointer is presented to achieve an ultrasensitive probe of S or the director's orientational angle θ. Using this scheme, we have demonstrated a real-time monitoring of the orientational process of cellulose nano-crystal molecules in solutions and measured the orientational direction of polymer nanowires. A typical precision on the order of 10−3 is achieved in the measurement of S and θ. Compared with the current existing techniques, the present scheme not only offers higher measurement precision but also maintains extreme cost-efficiency, thereby holding significance for the research of orientational materials and devices.

Förderung

  • National Natural Science Foundation of China
  • National Undergraduate Innovation and Entrepreneurship Training Program
  • Science and Technology Support Program of Sichuan Province

Zitieren

APA

Wang, C., Wang, Y., Liu, Y., Li, T., Luo, L., Zhang, S., & Zhang, Z. (2025). Ultrasensitive probing of nematic order parameter via weak measurement. Applied Physics Letters, 126(3). https://doi.org/10.1063/5.0250113

Vancouver

Wang C, Wang Y, Liu Y, Li T, Luo L, Zhang S, et al. Ultrasensitive probing of nematic order parameter via weak measurement. Applied Physics Letters. 2025;126(3). doi:10.1063/5.0250113

BibTeX
@article{Wang2025,
  author = {Wang, Changyou and Wang, Yunhan and Liu, Yurong and Li, Tong and Luo, Lan and Zhang, Sijie and Zhang, Zhiyou},
  title = {Ultrasensitive probing of nematic order parameter via weak measurement},
  journal = {Applied Physics Letters},
  year = {2025},
  volume = {126},
  number = {3},
  doi = {10.1063/5.0250113}
}
Kostenlos starten →