Interaction between arc root stagnation-transition and contact erosion during direct current air circuit breaker interruption

Wei Duan, Jing Li, Yuliang Bao, Hao Huang, Juncheng Yang, Shuxin Liu, Yundong Cao

Physics of Fluids · 01.01.2025 · 37 (1)

DOI: 10.1063/5.0239389 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 06.01.2025. Verfasst von Wei Duan und 6 weiteren Autor:innen. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 52 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Key Special Science and Technology Project of Liaoning Province, General Program of The Education Department of Liaoning Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The contact erosion during the arc duration affects the attachment position of arc roots, directly determining the arc motion speed. In this paper, a two-way coupling model is proposed to study the interaction between contact edge erosion and arc root stagnation-transition during direct current air arc interruption. A two-dimensional transient model for contact erosion and droplet splashing is established using an improved level-set method, combined with the magnetohydrodynamic model of arc plasma and contact energy transfer, considering the mass transfer, heat transfer, and fluid flow during the arc root stagnation-transition comprehensively. The model's accuracy is verified through experiments. The results show that the arc root stagnation forms molten pool or even droplet splashing. Vortices below the moving contact interfere favorably with arc root transition. However, contact deformation induced by erosion affects heat dissipation at the arc root, weakens the vortices' aerodynamic performance, hastens vortex bubble rupture, and delays arc root transition. Increasing breaking speed and arc-blowing magnetic induction intensity shortens stagnation time and reduces edge erosion. However, the breaking speed more than 5 m/s or the magnetic induction intensity more than 50 mT shows no significant improvement on the arc root transition speed, while erosion intensifies when magnetic induction intensity exceeds 50 mT.

Förderung

  • National Natural Science Foundation of China
  • Key Special Science and Technology Project of Liaoning Province
  • General Program of The Education Department of Liaoning Province

Zitieren

APA

Duan, W., Li, J., Bao, Y., Huang, H., Yang, J., Liu, S., & Cao, Y. (2025). Interaction between arc root stagnation-transition and contact erosion during direct current air circuit breaker interruption. Physics of Fluids, 37(1). https://doi.org/10.1063/5.0239389

Vancouver

Duan W, Li J, Bao Y, Huang H, Yang J, Liu S, et al. Interaction between arc root stagnation-transition and contact erosion during direct current air circuit breaker interruption. Physics of Fluids. 2025;37(1). doi:10.1063/5.0239389

BibTeX
@article{Duan2025,
  author = {Duan, Wei and Li, Jing and Bao, Yuliang and Huang, Hao and Yang, Juncheng and Liu, Shuxin and Cao, Yundong},
  title = {Interaction between arc root stagnation-transition and contact erosion during direct current air circuit breaker interruption},
  journal = {Physics of Fluids},
  year = {2025},
  volume = {37},
  number = {1},
  doi = {10.1063/5.0239389}
}