EUVIMEDEUVIMED entdecken
Crossref

Design, modeling, and control of coaxial integrated macro–micro composite actuator with high-precision and long-stroke

Caofeng Yu iD, Qilong Zhang iD, Yijun Wei iD, Zhihao Xiao, Kun Yang, Baokun Li iD

Review of Scientific Instruments · 01.01.2025 · 96 (1)

DOI: 10.1063/5.0237880 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 30.01.2025. Verfasst von Caofeng Yu und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechatronics Engineering, Anhui University of Science and Technology, Huainan 232001, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 19 Literaturangaben. Gefördert von: National Natural Science Foundation of China, State Key Laboratory of Fluid Power and Mechatronic Systems, China Postdoctoral Science Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a coaxial integrated macro–micro composite actuator. The macro-actuator of the macro–micro composite actuator is similar to a moving coil type voice coil motor, and a giant magnetostrictive actuator is installed coaxially inside it as a micro-actuator. In this work, kinetic models are established for both the macro-actuator and micro-actuator, and based on the models, an automatic disturbance rejection controller is adopted to control the macro-actuator, and a fuzzy sliding mode controller is adopted for the micro-actuator. In order to verify the actual performance of the proposed macro–micro composite actuator, a prototype was fabricated, and experimental results show that the macro-actuator can achieve a 10 mm step positioning error of 9 μm and a 30 mm step positioning error of 11 μm under a load of 1 kg. The resolution of the minimum PWM square wave change identification of the controlled micro-actuator is 0.047 μm, and the minimum displacement resolution of the micro-actuator is 0.15 μm. The micro-actuator is capable of achieving 1 μm steps with no displacement overshoot. In addition, when the positioning distance is 5 μm, there is a small amplitude overshoot of 0.18 μm. The final positioning accuracy of macro–micro composite positioning is within 350 nm.

Autor:innen und Institutionen

  • School of Mechatronics Engineering, Anhui University of Science and Technology, Huainan 232001, China.
  • State Key Laboratory of Fluid Power and Mechatronic Systems, Zhejiang University, Hangzhou 310027, China.

ORCID-Profile: Caofeng Yu, Qilong Zhang, Yijun Wei, Baokun Li

Förderung

  • National Natural Science Foundation of China
  • State Key Laboratory of Fluid Power and Mechatronic Systems
  • China Postdoctoral Science Foundation

Zitieren

APA

Yu, C., Zhang, Q., Wei, Y., Xiao, Z., Yang, K., & Li, B. (2025). Design, modeling, and control of coaxial integrated macro–micro composite actuator with high-precision and long-stroke. Review of Scientific Instruments, 96(1). https://doi.org/10.1063/5.0237880

Vancouver

Yu C, Zhang Q, Wei Y, Xiao Z, Yang K, Li B. Design, modeling, and control of coaxial integrated macro–micro composite actuator with high-precision and long-stroke. Review of Scientific Instruments. 2025;96(1). doi:10.1063/5.0237880

BibTeX
@article{Yu2025,
  author = {Yu, Caofeng and Zhang, Qilong and Wei, Yijun and Xiao, Zhihao and Yang, Kun and Li, Baokun},
  title = {Design, modeling, and control of coaxial integrated macro–micro composite actuator with high-precision and long-stroke},
  journal = {Review of Scientific Instruments},
  year = {2025},
  volume = {96},
  number = {1},
  doi = {10.1063/5.0237880}
}
Kostenlos starten →