EUVIMEDEUVIMED entdecken
Crossref

Microwave thermal imaging system for debonding detection of radar absorbing materials

Yihang Tu iD, Ziqiao Tang, Yang Qiu iD, Beibei Wang

Review of Scientific Instruments · 01.01.2025 · 96 (1)

DOI: 10.1063/5.0235306 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 08.01.2025. Verfasst von Yihang Tu und 3 weiteren Autor:innen. Beteiligte Einrichtung: School of Electronic Information and Electrical Engineering, Chengdu University, Chengdu 610106, China. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Sichuan Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, a microwave thermal imaging system (MTIS) has been presented for debonding detection of radar absorbing materials (RAMs). First, an overview of the mechanism underlying microwave heating and the fundamental principle of defect detection within RAMs is presented. Then, a multifunctional MTIS capable of performing both microwave lock-in thermography (MLIT) and long-pulse microwave thermography (LPMT) has been introduced, specifically tailored for the in situ inspection of RAMs. In addition, in this system, the detection area for a single scan is 90 * 90 mm2, with the emission source operating at a frequency of 5.8 GHz and boasting a maximum output power of 20 W. Next, based on MTIS, the above-mentioned two thermography techniques are applied to detect defects in RAMs. In addition, thermal contrast (Tc) and signal-to-noise ratio are introduced for the analysis of imaging results. Finally, the results show that LPMT can be used for preliminary detection of debonding defects in RAMs, while MLIT can be further used for detailed detection of debonding defects in RAMs. In addition, the minimum detection time of this MTIS is 45 s, and the minimum detectable defect aperture is 3 mm.

Autor:innen und Institutionen

  • School of Electronic Information and Electrical Engineering, Chengdu University, Chengdu 610106, China.
  • Chengdu Seekon Microwave Communications Co. Ltd., Chengdu 610091, China.
  • College of Public Health, Sichuan University, Chengdu 610041, China.

ORCID-Profile: Yihang Tu, Yang Qiu

Förderung

  • National Natural Science Foundation of China
  • Natural Science Foundation of Sichuan Province

Zitieren

APA

Tu, Y., Tang, Z., Qiu, Y., & Wang, B. (2025). Microwave thermal imaging system for debonding detection of radar absorbing materials. Review of Scientific Instruments, 96(1). https://doi.org/10.1063/5.0235306

Vancouver

Tu Y, Tang Z, Qiu Y, Wang B. Microwave thermal imaging system for debonding detection of radar absorbing materials. Review of Scientific Instruments. 2025;96(1). doi:10.1063/5.0235306

BibTeX
@article{Tu2025,
  author = {Tu, Yihang and Tang, Ziqiao and Qiu, Yang and Wang, Beibei},
  title = {Microwave thermal imaging system for debonding detection of radar absorbing materials},
  journal = {Review of Scientific Instruments},
  year = {2025},
  volume = {96},
  number = {1},
  doi = {10.1063/5.0235306}
}
Kostenlos starten →