Portable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis

A. Femenias, M. Erdem, P. Fomina, J. Scheuermann, U. Blazhko, S. Freitag, A. J. Bosman, R. Weih, J. Koeth, A. Kohler, R. Krska, G. I. J. Salentijn und 2 weitere

AIP Advances · 01.12.2024 · 14 (12)

DOI: 10.1063/5.0226248 ↗

Kurz gefasst

Fachartikel in der Zeitschrift AIP Advances, online erschienen am 05.12.2024. Verfasst von A. Femenias und 13 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Horizon 2020 Framework Program, Norges Forskningsråd.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Interband cascade lasers (ICL) are high output power mid-infrared light sources with low power consumption, serving as a viable alternative to more commonly applied quantum cascade lasers. The integration of ICLs with thin-film waveguides facilitates miniaturized sensing platforms based on the principles of evanescent field absorption toward tailorable high-fidelity portable mid-infrared (MIR) sensing solutions for on-site chemical analysis. The analytical performance of a MIR sensing system is presented combining a tunable interband cascade laser emitting at a wavelength range of 5.88–6.09 µm (1702–1641 cm−1) with a 6 µm GaAs/AlGaAs thin-film waveguide as the active transducer for customized evanescent field absorption analysis of food contaminants. A comparison of the analytical performance of the developed tICL-based system vs conventional Fourier-transform infrared spectroscopy is presented for the exemplary analysis of the Fusarium mycotoxin deoxynivalenol, a persistent food contaminant resulting from fungal infection. The thin-film waveguide enhances the sensitivity compared to conventional attenuated total reflection systems, revealing improved detection limits. The compact design of the system, along with the favorable analytical figures-of-merit and automated data processing, confirm the potential of the developed tICL-based spectrometer for on-site detection of food contaminants at various stages along the food supply chain.

Förderung

  • Horizon 2020 Framework Program
  • Norges Forskningsråd

Zitieren

APA

Femenias, A., Erdem, M., Fomina, P., Scheuermann, J., Blazhko, U., Freitag, S., Bosman, A. J., Weih, R., Koeth, J., Kohler, A., Krska, R., Salentijn, G. I. J., Ruggeri, F. S., & Mizaikoff, B. (2024). Portable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis. AIP Advances, 14(12). https://doi.org/10.1063/5.0226248

Vancouver

Femenias A, Erdem M, Fomina P, Scheuermann J, Blazhko U, Freitag S, et al. Portable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis. AIP Advances. 2024;14(12). doi:10.1063/5.0226248

BibTeX
@article{Femenias2024,
  author = {Femenias, A. and Erdem, M. and Fomina, P. and Scheuermann, J. and Blazhko, U. and Freitag, S. and Bosman, A. J. and Weih, R. and Koeth, J. and Kohler, A. and Krska, R. and Salentijn, G. I. J. and Ruggeri, F. S. and Mizaikoff, B.},
  title = {Portable tunable interband cascade laser spectrometer using thin-film waveguides for food contaminant analysis},
  journal = {AIP Advances},
  year = {2024},
  volume = {14},
  number = {12},
  doi = {10.1063/5.0226248}
}
Kostenlos starten →