Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond
Journal of Applied Physics · 28.01.2024 · 135 (4)
DOI: 10.1063/5.0184629 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Physics, online erschienen am 22.01.2024. Verfasst von Ryusei Okaniwa und 10 weiteren Autor:innen. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: MEXT Quantum Leap Flagship Program, MEXT/JSPS Grants-in-Aid for Scientific Research, Center for Spintronics Research Network, Keio University.
Abstract (Originalsprache)
The nitrogen-vacancy (NV) center is a promising candidate to realize practical quantum sensors with high sensitivity and high spatial resolution at room temperature and atmospheric pressure. In conventional high-frequency AC magnetometry with NV centers, the setup requires a pulse sequence with an appropriate time synchronization and strong microwave power. To avoid these practical difficulties, AC magnetometry using continuous-wave optically detected magnetic resonance (CW-ODMR) was recently demonstrated. That previous study utilized radio frequency (RF)-dressed states generated by the coherent interaction between the electron spin of the NV center and the RF wave. However, the drawback of this method is that the detectable frequency of the AC magnetic fields is fixed. Here, we propose and demonstrate frequency-tunable magnetic field sensing based on CW-ODMR. In the new sensing scheme, we obtain RF double-dressed states by irradiation with RF fields at two different frequencies. One creates the RF-dressed states and changes the frequency of the target AC field. The other is a target AC field that induces a change in the CW-ODMR spectrum by generating the RF double-dressed states through coherent interaction with the RF-dressed states. The sensitivity of our method is estimated to be comparable to or even higher than that of the conventional method based on the RF field with a single frequency. The estimated bandwidth is 7.5 MHz, higher than that of the conventional method using the RF-dressed states. Our frequency-tunable magnetic field sensor based on CW-ODMR paves the way for new applications in diamond devices.
Förderung
- MEXT Quantum Leap Flagship Program
- MEXT/JSPS Grants-in-Aid for Scientific Research
- Center for Spintronics Research Network, Keio University
- MEXT Leading Initiative for Excellent Young Reseachers
- JST PRESTO
- JST Moonshot R&D
- Kanazawa University CHOZEN Project 2022
- JST CREST
Zitieren
APA
Okaniwa, R., Mikawa, T., Matsuzaki, Y., Yamaguchi, T., Suzuki, R., Tokuda, N., Watanabe, H., Mizuochi, N., Sasaki, K., Kobayashi, K., & Ishi-Hayase, J. (2024). Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond. Journal of Applied Physics, 135(4). https://doi.org/10.1063/5.0184629
Vancouver
Okaniwa R, Mikawa T, Matsuzaki Y, Yamaguchi T, Suzuki R, Tokuda N, et al. Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond. Journal of Applied Physics. 2024;135(4). doi:10.1063/5.0184629
BibTeX
@article{Okaniwa2024,
author = {Okaniwa, Ryusei and Mikawa, Takumi and Matsuzaki, Yuichiro and Yamaguchi, Tatsuma and Suzuki, Rui and Tokuda, Norio and Watanabe, Hideyuki and Mizuochi, Norikazu and Sasaki, Kento and Kobayashi, Kensuke and Ishi-Hayase, Junko},
title = {Frequency-tunable magnetic field sensing using continuous-wave optically detected magnetic resonance with nitrogen-vacancy centers in diamond},
journal = {Journal of Applied Physics},
year = {2024},
volume = {135},
number = {4},
doi = {10.1063/5.0184629}
}
EUVIMED