Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer
Review of Scientific Instruments · 01.01.2024 · 95 (1)
DOI: 10.1063/5.0177603 ↗Kurz gefasst
Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 29.01.2024. Verfasst von Alicia M Anderson und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, University of Lethbridge, 4401 University Dr. W, Lethbridge, Alberta T1K 3M4, Canada. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Sciences and Engineering Research Council of Canada, Canada Foundation for Innovation, Alberta Innovates.
Abstract (Originalsprache)
Recent advances in far-infrared detector technology have led to increases in raw sensitivity of more than an order of magnitude over previous state-of-the-art detectors. With such sensitivity, photon noise becomes the dominant noise component, even when using cryogenically cooled optics, unless a method of restricting the spectral bandpass is employed. The leading instrument concept features reflecting diffraction gratings, which post-disperse the light that has been modulated by a polarizing Fourier transform spectrometer (FTS) onto a detector array, thereby reducing the photon noise on each detector. This paper discusses the development of a cryogenic (4 K) diffraction grating spectrometer that operates over the wavelength range of 285 to 500 μm and was used to post-disperse the output from a room-temperature polarizing FTS. Measurements of the grating spectral response and diffraction efficiency are presented as a function of both wavelength and polarization to characterize the instrumental performance.
Autor:innen und Institutionen
- Department of Physics and Astronomy, University of Lethbridge, 4401 University Dr. W, Lethbridge, Alberta T1K 3M4, Canada.
- Blue Sky Spectroscopy Inc., Lethbridge, Alberta T1J 0N9, Canada.
- Cavendish Laboratory, Astrophysics Group, University of Cambridge, J. J. Thomson Avenue, Cambridge CB3 0HE, United Kingdom.
- School of Physics and Astronomy, Cardiff University, Cardiff CF24 3AA, Wales, United Kingdom.
ORCID-Profile: Alicia M Anderson, David A Naylor, Brad G Gom, Matthew A Buchan, Adam J Christiansen, Ian T Veenendaal
Förderung
- Natural Sciences and Engineering Research Council of Canada
- Canada Foundation for Innovation
- Alberta Innovates
- Canadian Space Agency
- CMC Microsystems
Zitieren
APA
Anderson, A. M., Naylor, D. A., Gom, B. G., Buchan, M. A., Christiansen, A. J., & Veenendaal, I. T. (2024). Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer. Review of Scientific Instruments, 95(1). https://doi.org/10.1063/5.0177603
Vancouver
Anderson AM, Naylor DA, Gom BG, Buchan MA, Christiansen AJ, Veenendaal IT. Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer. Review of Scientific Instruments. 2024;95(1). doi:10.1063/5.0177603
BibTeX
@article{Anderson2024,
author = {Anderson, Alicia M and Naylor, David A and Gom, Brad G and Buchan, Matthew A and Christiansen, Adam J and Veenendaal, Ian T},
title = {Development and validation of a cryogenic far-infrared diffraction grating spectrometer used to post-disperse the output from a Fourier transform spectrometer},
journal = {Review of Scientific Instruments},
year = {2024},
volume = {95},
number = {1},
doi = {10.1063/5.0177603}
}
EUVIMED