EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensitivity of acoustofluidic particle manipulation to microchannel height in standing surface acoustic wave-based microfluidic devices

Yiming Li, Dongfang Liang, Alexandre Kabla, Yuning Zhang, Xin Yang

Physics of Fluids · 01.12.2023 · 35 (12)

DOI: 10.1063/5.0177118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physics of Fluids, online erschienen am 26.12.2023. Verfasst von Yiming Li und 4 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Natural Environment Research Council, Isaac New Trust, Energy Policy Research Group.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, the flow and particle trajectories, induced by standing surface acoustic waves (SSAWs) in a poly-dimethylsiloxane microchannel, are investigated by establishing a two-dimensional cross-sectional model with the finite element method and improved boundary conditions. Extensive parametric studies are conducted regarding the channel height, ranging from 0.2 to 4.0 times the spacing of the repetitive vertical interference pattern, to investigate its influences on the flow field and microparticle aggregation. The first-order flow field is found to be related to the channel height, exhibiting a periodic spatial distribution and oscillatory variation in its amplitude as the height changes. We theoretically analyze the propagation mechanism of the acoustic waves in the vertical direction and thus determine the periodicity of the wave interference pattern. Furthermore, we find that the speed of the particle aggregation is a function of the channel height, so the channel height can be optimized to maximize the strength of the first-order flow field and thus minimize the time of particle aggregation. The optimum heights can reduce the aggregation time by up to 76%. In addition, the acoustophoretic motions of microparticles exhibit a spatially dependent pattern when the channel height becomes larger than a quarter of the wavelength of the SAW, which can be explained by the change in the ratio between the radiation force and the streaming drag force from position to position. Our findings provide guidelines to the design and optimization of SSAW-based acoustofluidic devices.

Förderung

  • Natural Environment Research Council
  • Isaac New Trust
  • Energy Policy Research Group

Zitieren

APA

Li, Y., Liang, D., Kabla, A., Zhang, Y., & Yang, X. (2023). Sensitivity of acoustofluidic particle manipulation to microchannel height in standing surface acoustic wave-based microfluidic devices. Physics of Fluids, 35(12). https://doi.org/10.1063/5.0177118

Vancouver

Li Y, Liang D, Kabla A, Zhang Y, Yang X. Sensitivity of acoustofluidic particle manipulation to microchannel height in standing surface acoustic wave-based microfluidic devices. Physics of Fluids. 2023;35(12). doi:10.1063/5.0177118

BibTeX
@article{Li2023,
  author = {Li, Yiming and Liang, Dongfang and Kabla, Alexandre and Zhang, Yuning and Yang, Xin},
  title = {Sensitivity of acoustofluidic particle manipulation to microchannel height in standing surface acoustic wave-based microfluidic devices},
  journal = {Physics of Fluids},
  year = {2023},
  volume = {35},
  number = {12},
  doi = {10.1063/5.0177118}
}
Kostenlos starten →