A method to generate perfusable physiologic-like vascular channels within a liver-on-chip model
Biomicrofluidics · 01.12.2023 · 17 (6)
DOI: 10.1063/5.0170606 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomicrofluidics, online erschienen am 04.12.2023. Verfasst von E Ferrari und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronics, Information and Bioengineering, Politecnico di Milano, via Camillo Golgi 39, 20134 Milano (MI), Italy. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: HORIZON EUROPE Marie Sklodowska-Curie Actions.
Abstract (Originalsprache)
The human vasculature is essential in organs and tissues for the transport of nutrients, metabolic waste products, and the maintenance of homeostasis. The integration of vessels in in vitro organs-on-chip may, therefore, improve the similarity to the native organ microenvironment, ensuring proper physiological functions and reducing the gap between experimental research and clinical outcomes. This gap is particularly evident in drug testing and the use of vascularized models may provide more realistic insights into human responses to drugs in the pre-clinical phases of the drug development pipeline. In this context, different vascularized liver models have been developed to recapitulate the architecture of the hepatic sinusoid, exploiting either porous membranes or bioprinting techniques. In this work, we developed a method to generate perfusable vascular channels with a circular cross section within organs-on-chip without any interposing material between the parenchyma and the surrounding environment. Through this technique, vascularized liver sinusoid-on-chip systems with and without the inclusion of the space of Disse were designed and developed. The recapitulation of the Disse layer, therefore, a gap between hepatocytes and endothelial cells physiologically present in the native liver milieu, seems to enhance hepatic functionality (e.g., albumin production) compared to when hepatocytes are in close contact with endothelial cells. These findings pave the way to numerous further uses of microfluidic technologies coupled with vascularized tissue models (e.g., immune system perfusion) as well as the integration within multiorgan-on-chip settings.
Autor:innen und Institutionen
- Department of Electronics, Information and Bioengineering, Politecnico di Milano, via Camillo Golgi 39, 20134 Milano (MI), Italy.
- Istituto Europeo di Oncologia, via Adamello 16, 20139 Milano (MI), Italy.
- BiomimX Srl, viale Decumano 41, 20157 Milano (MI), Italy.
- Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, Massachusetts 02139, USA.
ORCID-Profile: E Ferrari, E Monti, C Cerutti, R Visone, P Occhetta, L G Griffith, M Rasponi
Förderung
- HORIZON EUROPE Marie Sklodowska-Curie Actions
Zitieren
APA
Ferrari, E., Monti, E., Cerutti, C., Visone, R., Occhetta, P., Griffith, L. G., & Rasponi, M. (2023). A method to generate perfusable physiologic-like vascular channels within a liver-on-chip model. Biomicrofluidics, 17(6). https://doi.org/10.1063/5.0170606
Vancouver
Ferrari E, Monti E, Cerutti C, Visone R, Occhetta P, Griffith LG, et al. A method to generate perfusable physiologic-like vascular channels within a liver-on-chip model. Biomicrofluidics. 2023;17(6). doi:10.1063/5.0170606
BibTeX
@article{Ferrari2023,
author = {Ferrari, E and Monti, E and Cerutti, C and Visone, R and Occhetta, P and Griffith, L G and Rasponi, M},
title = {A method to generate perfusable physiologic-like vascular channels within a liver-on-chip model},
journal = {Biomicrofluidics},
year = {2023},
volume = {17},
number = {6},
doi = {10.1063/5.0170606}
}
EUVIMED