EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

A high-sensitivity fiber Bragg grating sensor for displacement measurement in structural health monitoring

Zhenjing Yao iD, Mingyang Li, Guangmin Li iD, Mengtao Xing iD, Ning Chen

Review of Scientific Instruments · 01.09.2023 · 94 (9)

DOI: 10.1063/5.0156890 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Review of Scientific Instruments, online erschienen am 15.09.2023. Verfasst von Zhenjing Yao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Disaster Prevention, Sanhe 065201, China. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Langfang Science and Technology Support Plan Project, Open Fund of Hebei Key Laboratory of Seismic Disaster Instrument and Monitoring Technology, Special Fund of Fundamental Scientific Research Business Expense for Higher School of Central Government.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Displacement measurement is of great significance to monitor the crack variation and ensure the health of building structures. Aiming at the problems of low sensitivity and high temperature error of fiber Bragg grating (FBG) displacement sensors in displacement monitoring, this paper presents an adjustable cantilever beam displacement sensor with the FBGs as the sensing element. The sensor adds double FBGs on the relative surfaces of the equal-strength cantilever beam, which increases the bending deformation on the FBG of the beam surface to improve the sensitivity and realize the temperature compensation of the sensor. By adding an adjustable external rod structure between a flexible spring and a fixed foot stand, the sensor can regulate the range of initial crack width for different occasions. A theoretical analysis of the displacement sensor is performed, and the simulation analysis and optimization design for the structural parameters of the cantilever beam elastic sensitive element are implemented by adopting SolidWorks and ANSYS software. Finally, a displacement testing platform is constructed to test its performance. Experimental results show that this design has a high sensitivity coefficient of 39.47 pm/mm and a temperature coefficient of 1.04 pm/°C in the range of initial crack width from 0 to 110 mm or from 0 to 130 mm depending on different monitoring situations. Furthermore, good linearity, hysteresis delay, repeatability, and temperature compensation performance have also been demonstrated.

Autor:innen und Institutionen

  • Institute of Disaster Prevention, Sanhe 065201, China.
  • Hebei Key Laboratory of Seismic Disaster Instrument and Monitoring Technology, Sanhe 065201, China.

ORCID-Profile: Zhenjing Yao, Guangmin Li, Mengtao Xing

Förderung

  • Langfang Science and Technology Support Plan Project
  • Open Fund of Hebei Key Laboratory of Seismic Disaster Instrument and Monitoring Technology
  • Special Fund of Fundamental Scientific Research Business Expense for Higher School of Central Government
  • Natioanl Natural Science Foundation of China

Zitieren

APA

Yao, Z., Li, M., Li, G., Xing, M., & Chen, N. (2023). A high-sensitivity fiber Bragg grating sensor for displacement measurement in structural health monitoring. Review of Scientific Instruments, 94(9). https://doi.org/10.1063/5.0156890

Vancouver

Yao Z, Li M, Li G, Xing M, Chen N. A high-sensitivity fiber Bragg grating sensor for displacement measurement in structural health monitoring. Review of Scientific Instruments. 2023;94(9). doi:10.1063/5.0156890

BibTeX
@article{Yao2023,
  author = {Yao, Zhenjing and Li, Mingyang and Li, Guangmin and Xing, Mengtao and Chen, Ning},
  title = {A high-sensitivity fiber Bragg grating sensor for displacement measurement in structural health monitoring},
  journal = {Review of Scientific Instruments},
  year = {2023},
  volume = {94},
  number = {9},
  doi = {10.1063/5.0156890}
}
Kostenlos starten →