Time-walk and jitter correction in SNSPDs at high count rates
Applied Physics Letters · 23.01.2023 · 122 (4)
DOI: 10.1063/5.0129147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Applied Physics Letters, online erschienen am 27.01.2023. Verfasst von Andrew Mueller und 7 weiteren Autor:innen. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Aeronautics and Space Administration, Defense Advanced Research Projects Agency, National Aeronautics and Space Administration SCaN.
Abstract (Originalsprache)
Superconducting nanowire single-photon detectors (SNSPDs) are a leading detector type for time correlated single photon counting, especially in the near-infrared. When operated at high count rates, SNSPDs exhibit increased timing jitter caused by internal device properties and features of the RF amplification chain. Variations in RF pulse height and shape lead to variations in the latency of timing measurements. To compensate for this, we demonstrate a calibration method that correlates delays in detection events with the time elapsed between pulses. The increase in jitter at high rates can be largely canceled in software by applying corrections derived from the calibration process. We demonstrate our method with a single-pixel tungsten silicide SNSPD and show it decreases high count rate jitter. The technique is especially effective at removing a long tail that appears in the instrument response function at high count rates. At a count rate of 11.4 MCounts/s, we reduce the full width at 1% maximum level (FW1%M) by 45%. The method, therefore, enables certain quantum communication protocols that are rate-limited by the FW1%M metric to operate almost twice as fast.
Förderung
- National Aeronautics and Space Administration
- Defense Advanced Research Projects Agency
- National Aeronautics and Space Administration SCaN
- Alliance for Quantum Technologies, California Institute of Technology
- Brinson Foundation
- President and Director's Research and Development Fund, Jet Propulsion Laboratory
- Fermilab Quantum Institute
Zitieren
APA
Mueller, A., Wollman, E. E., Korzh, B., Beyer, A. D., Narvaez, L., Rogalin, R., Spiropulu, M., & Shaw, M. D. (2023). Time-walk and jitter correction in SNSPDs at high count rates. Applied Physics Letters, 122(4). https://doi.org/10.1063/5.0129147
Vancouver
Mueller A, Wollman EE, Korzh B, Beyer AD, Narvaez L, Rogalin R, et al. Time-walk and jitter correction in SNSPDs at high count rates. Applied Physics Letters. 2023;122(4). doi:10.1063/5.0129147
BibTeX
@article{Mueller2023,
author = {Mueller, Andrew and Wollman, Emma E. and Korzh, Boris and Beyer, Andrew D. and Narvaez, Lautaro and Rogalin, Ryan and Spiropulu, Maria and Shaw, Matthew D.},
title = {Time-walk and jitter correction in SNSPDs at high count rates},
journal = {Applied Physics Letters},
year = {2023},
volume = {122},
number = {4},
doi = {10.1063/5.0129147}
}
EUVIMED