Liquefied natural gas (LNG) cylindrical storage tanks are critical assets in the energy supply chain. Seismic damage to these tanks can threaten life safety, harm the environment, and trigger fires or explosions. Due to their large size, hazardous contents, and dual-containment configuration, full-scale cryogenic testing is impractical. Consequently, prior studies have relied on added-mass idealizations using water surrogates, which cannot adequately capture the coupled fluid–structure interaction (FSI) and nonlinear sloshing effects that govern the seismic response. This study uses advanced numerical analysis to model FSI and quantify the dynamic behavior of LNG cylindrical tanks subjected to recorded earthquake motions. The finite-element model is first validated against a benchmark cylindrical concrete tank from the literature, showing close agreement with published numerical predictions and established theoretical solutions. The model predicted a maximum impulsive hydrodynamic pressure of 16.01 kPa, which is within 0.1% of the analytical value of 16.03 kPa and within 2.5% of the previously reported numerical result of 16.42 kPa, demonstrating strong agreement. A subsequent parametric study on an LNG storage tank evaluates nonlinear sloshing, wall deformation, von Mises stress, and time histories of sloshing displacement and wave height under a suite of ground motions. Relative to static conditions, seismic loading increases von Mises stresses by up to 50% and produces extreme sloshing wave heights of up to 690 mm for an input peak ground acceleration ( PGA ) = 0.62 g . The maximum sloshing heights are approximately 303 and 130 mm for PGA = 0.57 and 0.47 g, respectively, underscoring the sensitivity of free-surface motion to input intensity. The results demonstrate FSI’s dominant role in tank performance and the need for nonlinear dynamic analysis in design. The findings provide practical guidance to enhance the seismic safety and resilience of LNG storage tanks.

Zitieren

APA

Ullah, S., & Mamaghani, I. H. P. (2027). Seismic Performance Evaluation of LNG Storage Tanks under Varying Input Intensities. Journal of Structural Design and Construction Practice, 32(2). https://doi.org/10.1061/jsdccc.sceng-2292

Vancouver

Ullah S, Mamaghani IHP. Seismic Performance Evaluation of LNG Storage Tanks under Varying Input Intensities. Journal of Structural Design and Construction Practice. 2027;32(2). doi:10.1061/jsdccc.sceng-2292

BibTeX
@article{Ullah2027,
  author = {Ullah, Shafqat and Mamaghani, Iraj H. P.},
  title = {Seismic Performance Evaluation of LNG Storage Tanks under Varying Input Intensities},
  journal = {Journal of Structural Design and Construction Practice},
  year = {2027},
  volume = {32},
  number = {2},
  doi = {10.1061/jsdccc.sceng-2292}
}
Kostenlos starten →