EUVIMEDEUVIMED entdecken
Crossref

Cyclic Response of Concrete Columns Reinforced with Quantum Tech–Produced 600-Grade Bars

Khondaker Sakil Ahmed, Md Ziaul Hasan, Abdullah Al Moneim, Saiful Islam, Raquib Ahsan

Journal of Structural Design and Construction Practice · 01.05.2027 · 32 (2)

DOI: 10.1061/jsdccc.sceng-2175 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Structural Design and Construction Practice, erschienen am 01.05.2027. Verfasst von Khondaker Sakil Ahmed und 4 weiteren Autor:innen. Die Arbeit nennt 80 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

High-strength rebar (HSR) may enhance the strength and stiffness of concrete columns while minimizing rebar usage and congestion, hence reducing CO 2 emissions and improving construction quality; however, their seismic performance remains under investigation. This study investigates the seismic response of full-scale RC columns reinforced with 600 grade (a nominal yield strength of 600 MPa and over) HSR under quasi-static reversed cyclic loads. To determine the hysteretic behavior of HSR-reinforced concrete columns, seven full-scale specimens were prepared, cured, and tested under combined axial and cyclic loads until complete failure. The varying parameters of HSR-reinforced columns are reinforcement ratio, concrete grades, and rebar diameters. Hysteresis loops and skeleton curves obtained from test results at different key stages, such as yielding, peak, and ultimate capacity, crack propagation, failure mechanism, and bar buckling, were analyzed and compared with those of the normal-strength (500 MPa) reinforced columns. Various parameters related to the cyclic capacity of HSR columns, such as energy dissipation, equivalent viscous damping, and stiffness degradation, were also analyzed explicitly. HSR-reinforced columns (HSRC) showed an improved performance in terms of increased strength, stiffness, ductility, and energy dissipation compared with that of the normal-strength rebar (NSR)-reinforced column (NSRC). For example, for 30-MPa concrete, HSRC showed 7% higher ultimate load than that of the NSRC, where other parameters remained the same. Similar observations were found for the 40-MPa concrete, where a maximum load of 59.55 kN was recorded, outperforming the NSRC specimen and indicating that using a higher-grade concrete with HSR will significantly increase the capacity of the columns. Experimental results also revealed that rebar diameter and elongation are significantly correlated to the seismic drift capacity of the columns, with smaller diameters showing a lower drift ratio capacity, possibly due to the premature rebar buckling, which was observed to happen up to a diameter of 16 mm regardless of rebar strength. Furthermore, the analytical estimation of drift ratios corresponding to the bar-buckling limit state of the HSRCs requires the revision of existing analytical models.

Zitieren

APA

Ahmed, K. S., Hasan, M. Z., Moneim, A. A., Islam, S., & Ahsan, R. (2027). Cyclic Response of Concrete Columns Reinforced with Quantum Tech–Produced 600-Grade Bars. Journal of Structural Design and Construction Practice, 32(2). https://doi.org/10.1061/jsdccc.sceng-2175

Vancouver

Ahmed KS, Hasan MZ, Moneim AA, Islam S, Ahsan R. Cyclic Response of Concrete Columns Reinforced with Quantum Tech–Produced 600-Grade Bars. Journal of Structural Design and Construction Practice. 2027;32(2). doi:10.1061/jsdccc.sceng-2175

BibTeX
@article{Ahmed2027,
  author = {Ahmed, Khondaker Sakil and Hasan, Md Ziaul and Moneim, Abdullah Al and Islam, Saiful and Ahsan, Raquib},
  title = {Cyclic Response of Concrete Columns Reinforced with Quantum Tech–Produced 600-Grade Bars},
  journal = {Journal of Structural Design and Construction Practice},
  year = {2027},
  volume = {32},
  number = {2},
  doi = {10.1061/jsdccc.sceng-2175}
}
Kostenlos starten →