Hydrological and Hydrodynamical Mesoscale Modeling of a Dam Failure in Brazil: Risk and Direct Tangible Damage Assessment under Different Probability Scenarios and Methodologies
Journal of Performance of Constructed Facilities · 01.02.2027 · 41 (1)
DOI: 10.1061/jpcfev.cfeng-5602 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Performance of Constructed Facilities, erschienen am 01.02.2027. Verfasst von Daniel de Abreu Henriques und 1 weiteren Autor:innen. Die Arbeit nennt 67 Literaturangaben.
Abstract (Originalsprache)
The Lagoa do Nado earth dam, constructed in the 1940s in Brazil, failed on November 13, 2024, during a rainfall event with an estimated 13-year return period that caused overtopping. The spillway operated with stop logs that remained improperly in place during the event. This paper presents a back-analysis of the failure to evaluate the overtopping conditions and assess the adequacy of spillway capacity. Hydrological simulations using Soil Conservation Service-curve number (SCS-CN), Modified Puls, and HEC-HMS indicated that the structure was unable to safely route even a low-return-period storm, because overtopping still would have occurred even without spillway obstruction. Two-dimensional hydrodynamical modeling of the mesoscale study area, based on shallow-water equations in HEC-RAS, satisfactorily reproduced the observed flood, which remained confined to the dam’s park area and did not reach downstream neighborhoods. Two higher return periods (200 and 1,000 years) were simulated to support hydrodynamic hazard assessment and direct tangible damage estimation for buildings. Substantial risk levels were identified both immediately downstream of the breach and along a nearby street bordered by buildings. Although the inundation extent remained similar among the simulated scenarios, flood depths varied and were used as input for relative synthetic damage functions combined with the Basic Unit Construction Cost (CUB) for the state of Minas Gerais. This approach yielded results comparable to those obtained using traditional empirical-absolute damage functions applied in the state. A hypothetical spillway redesign was developed to safely convey a 1,000-year event. The results indicated a limited reduction of direct building damage, with measurable benefits observed only for events with return periods exceeding 200 years. Nevertheless, the cost–benefit analysis demonstrated economic advantages associated with this flood-control measure. The proposed framework may support improved monitoring and oversight of dams located in urban areas by public agencies.
Zitieren
APA
Henriques, D. D. A., & Villar, L. F. D. S. (2027). Hydrological and Hydrodynamical Mesoscale Modeling of a Dam Failure in Brazil: Risk and Direct Tangible Damage Assessment under Different Probability Scenarios and Methodologies. Journal of Performance of Constructed Facilities, 41(1). https://doi.org/10.1061/jpcfev.cfeng-5602
Vancouver
Henriques DDA, Villar LFDS. Hydrological and Hydrodynamical Mesoscale Modeling of a Dam Failure in Brazil: Risk and Direct Tangible Damage Assessment under Different Probability Scenarios and Methodologies. Journal of Performance of Constructed Facilities. 2027;41(1). doi:10.1061/jpcfev.cfeng-5602
BibTeX
@article{Henriques2027,
author = {Henriques, Daniel de Abreu and Villar, Lúcio Flávio de Souza},
title = {Hydrological and Hydrodynamical Mesoscale Modeling of a Dam Failure in Brazil: Risk and Direct Tangible Damage Assessment under Different Probability Scenarios and Methodologies},
journal = {Journal of Performance of Constructed Facilities},
year = {2027},
volume = {41},
number = {1},
doi = {10.1061/jpcfev.cfeng-5602}
}