EUVIMEDEUVIMED entdecken
Crossref

Validation and Optimization of Visual and Nonvisual Lighting Performance Based on Multispectral Modeling in Badminton Sports Halls

Tiara Nurhuda, Rizki A. Mangkuto, Gontar Amin, Ikhwan Muttaqien Hermawan, R. Sugeng Joko Sarwono, Narendra Kurnia Putra

Journal of Architectural Engineering · 01.12.2026 · 32 (4)

DOI: 10.1061/jaeied.aeeng-2361 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Architectural Engineering, erschienen am 01.12.2026. Verfasst von Tiara Nurhuda und 5 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Lighting is an important element in building design, including sports halls. Lighting design for badminton sports halls traditionally emphasizes visual criteria while overlooking nonvisual aspects. This study aims to optimize the electric lighting design in a badminton sports hall to meet the minimum targets for predetermined visual and nonvisual parameters, following a prior validation of the simulation tool. The multispectral lighting simulation tool adaptive lighting for alertness (ALFA) was validated by comparing simulated and measured spectral irradiance data across five courts, showing an acceptable level of agreement. Sensitivity analysis quantified the practical impact of design variables, revealing that luminaire tilt angle had the largest nominal effect size on illuminance ( r = −0.96) and nonvisual metrics ( r = −0.77), whereas surface reflectance primarily influenced vertical illuminance ( r = 0.60). The target output parameters are average horizontal illuminance ( E h ,ave ) ≥ 750 lx, melanopic equivalent daylight illuminance (mel-EDI ave ) ≥ 250 lx, uniformity ( U ave ) ≥ 0.7, and circadian stimulus (CS d ) ≥ 0.43. Optimization was performed using the weighted scoring method to determine the best design combination, which was achieved at a luminaire height of 11 m, a tilt angle of 30°, a court floor reflectance of 0.2, and interluminaire distances of dx = 0.45 m and dy = 1.8 m. The luminous flux of each luminaire was adjusted to 15,065, 11,337, 11,108, 11,256, and 15,630 lm for Courts 1–5, respectively, to satisfy all targets.

Zitieren

APA

Nurhuda, T., Mangkuto, R. A., Amin, G., Hermawan, I. M., Sarwono, R. S. J., & Putra, N. K. (2026). Validation and Optimization of Visual and Nonvisual Lighting Performance Based on Multispectral Modeling in Badminton Sports Halls. Journal of Architectural Engineering, 32(4). https://doi.org/10.1061/jaeied.aeeng-2361

Vancouver

Nurhuda T, Mangkuto RA, Amin G, Hermawan IM, Sarwono RSJ, Putra NK. Validation and Optimization of Visual and Nonvisual Lighting Performance Based on Multispectral Modeling in Badminton Sports Halls. Journal of Architectural Engineering. 2026;32(4). doi:10.1061/jaeied.aeeng-2361

BibTeX
@article{Nurhuda2026,
  author = {Nurhuda, Tiara and Mangkuto, Rizki A. and Amin, Gontar and Hermawan, Ikhwan Muttaqien and Sarwono, R. Sugeng Joko and Putra, Narendra Kurnia},
  title = {Validation and Optimization of Visual and Nonvisual Lighting Performance Based on Multispectral Modeling in Badminton Sports Halls},
  journal = {Journal of Architectural Engineering},
  year = {2026},
  volume = {32},
  number = {4},
  doi = {10.1061/jaeied.aeeng-2361}
}