Prospective Long-Term Follow-Up of the Cementless Bicontact Hip Stem with Plasmapore Coating
Zeitschrift für Orthopädie und ihre Grenzgebiete · 01.01.2007 · 145 (S 1) · S3-S8
DOI: 10.1055/s-2007-965652 ↗Kurz gefasst
Fachartikel in der Zeitschrift Zeitschrift für Orthopädie und ihre Grenzgebiete, erschienen am 01.01.2007. Verfasst von U Ochs und 6 weiteren Autor:innen. Beteiligte Einrichtung: BG Trauma Centre, University of Tuebingen, Schnarrenbergstrasse 95, Tuebingen, Germany. uochs@bgu-tuebingen.de. Hauptthemen laut MEDLINE: Coated Materials, Biocompatible, Hip Prosthesis, Titanium. Die Arbeit wurde bisher 17-mal zitiert (Crossref).
Abstract (Originalsprache)
AIM: A prospective long-term study of the first 250 cementless Bicontact stems implanted in the BG Trauma Centre, Tuebingen, Germany. METHOD: All of the patients in this series (treatment period June 1987 to April 1990) who were still contactable were invited for clinical and radiological follow-up. The radiographs were analysed for signs of loosening in the form of Gruen lysis zones, stress shielding, subsidence behaviour, heterotopic ossification and spot welds. RESULTS: The average follow-up period was 17.8 (16.7 - 19.5) years. The overall rate of follow-up was 65 % (162 of 250) and 91 % of patients who were still alive (162 of 179). The average patient age was 56.2 years at the time of operation and 74.0 years at follow-up. The average HHS was 81.6 points. In the course of the first 10 years (up to 03/1998), a total of 8 stem revisions had to be performed. In the period from 03/1998 to 01/2007, 2 cases of loosening requiring revision occurred in the patients still alive at the time of follow-up. The survival rate calculated was thus 95.6 %. CONCLUSION: These outstanding results provide enduring support for the philosophy of the cementless and bone-preserving fixation principles underlying the Bicontact hip stem with proximal intertrochanteric transmission of forces and high primary rotational stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- BG Trauma Centre, University of Tuebingen, Schnarrenbergstrasse 95, Tuebingen, Germany. uochs@bgu-tuebingen.de
Zitieren
APA
Ochs, U., Eingartner, C., Volkmann, R., Ochs, B. G., Huber, C., Weller, S., & Weise, K. (2007). Prospective Long-Term Follow-Up of the Cementless Bicontact Hip Stem with Plasmapore Coating. Zeitschrift für Orthopädie und ihre Grenzgebiete, 145(S 1), S3-S8. https://doi.org/10.1055/s-2007-965652
Vancouver
Ochs U, Eingartner C, Volkmann R, Ochs BG, Huber C, Weller S, et al. Prospective Long-Term Follow-Up of the Cementless Bicontact Hip Stem with Plasmapore Coating. Zeitschrift für Orthopädie und ihre Grenzgebiete. 2007;145(S 1):S3-S8. doi:10.1055/s-2007-965652
BibTeX
@article{Ochs2007,
author = {Ochs, U and Eingartner, C and Volkmann, R and Ochs, B G and Huber, C and Weller, S and Weise, K},
title = {Prospective Long-Term Follow-Up of the Cementless Bicontact Hip Stem with Plasmapore Coating},
journal = {Zeitschrift für Orthopädie und ihre Grenzgebiete},
year = {2007},
volume = {145},
number = {S 1},
pages = {S3--S8},
doi = {10.1055/s-2007-965652}
}
EUVIMED