Single-Balloon Enteroscopy versus Double-Balloon Enteroscopy: Do We Really Need the Second Balloon?
Journal of Digestive Endoscopy · 01.03.2026 · 17 (S 01 S 01) · S1-S138
DOI: 10.1055/s-0046-1828841 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Digestive Endoscopy, erschienen am 01.03.2026. Verfasst von Zubin Dev Sharma. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Deep enteroscopy transformed the diagnosis and management of small bowel disease, which was previously accessible only through intraoperative or push enteroscopy. Double-balloon enteroscopy (DBE), introduced in 2001, uses two balloons—one on the endoscope tip and one on the overtube—combined with a push-and-pull technique to achieve deep intubation of the small bowel. Single-balloon enteroscopy (SBE) was later developed as a technically simpler alternative, retaining only the overtube balloon and relying on angulation and suction at the endoscope tip for anchoring. Because SBE eliminates one balloon and its associated inflation/deflation cycle, it is generally regarded as faster to learn and quicker to perform, but whether this simplification comes at the cost of diagnostic or therapeutic performance remains debated.
Aim
To compare SBE and DBE with respect to diagnostic yield, therapeutic yield, depth of insertion, rate of complete enteroscopy, procedure time, and complication rate, and to evaluate whether the additional balloon in DBE confers a clinically meaningful advantage.
Methods
A comparative review of prospective, retrospective, and randomized controlled studies, along with pooled meta-analytic data, was undertaken. Outcome measures assessed across studies included diagnostic yield, therapeutic success, technical/insertion success, rate of total (complete) enteroscopy, mean procedure and insertion time, and adverse event rates. Where available, pooled risk ratios (RRs) with 95% confidence intervals (CIs) from meta-analyses of randomized trials were used to synthesize comparative outcomes.
Results
Across the available randomized trials (largely pooled from four randomized controlled trials totaling around 375 patients) and multiple retrospective cohorts, DBE was found to be superior to SBE for complete visualization of the small bowel, while diagnostic yield, therapeutic yield, and complication rates were statistically similar between the two techniques. A separate meta-analysis using a broader outcome set reported that DBE did not show a significant advantage over SBE in diagnostic or therapeutic yield, failure rates, insertion depth, procedure time, or complete enteroscopy rates, suggesting overall comparable performance once heterogeneity across operators and centers is accounted for. Individual studies have shown some inconsistency: at least one prospective series reported a substantially higher diagnostic yield and complete-enteroscopy rate with DBE, while a separate single-center retrospective analysis found SBE to have a higher diagnostic rate via the anal (retrograde) approach specifically, with no significant difference by the oral route. Such discrepancies have generally been attributed to differences in operator experience, learning curve, and case-mix rather than to an intrinsic mechanical superiority of either device. Complication rates—including pancreatitis, perforation, and bleeding—have been consistently low and statistically indistinguishable between the two modalities across pooled analyses. Procedure time tends to be shorter with SBE in several series, likely reflecting the simpler balloon-handling mechanics, though this has not translated into a consistent difference in overall diagnostic or therapeutic success.
Conclusion
Current evidence indicates that while DBE may achieve a modestly higher rate of complete small bowel enteroscopy, this does not consistently translate into superior diagnostic yield, therapeutic success, or safety compared with SBE. Given that SBE offers a simpler mechanical design, a shorter learning curve, and generally shorter procedure times, it appears to be a reasonable and comparably effective alternative to DBE in most clinical settings. The “second balloon” in DBE may add incremental value primarily in cases requiring maximal depth of insertion or where complete enteroscopy is specifically the clinical goal, but for routine diagnostic and therapeutic indications, the marginal benefit appears limited. Larger, adequately powered randomized trials with standardized operator experience are needed to definitively establish whether the added complexity of DBE is justified across the full range of small bowel indications, or whether SBE can serve as the default technique in most enteroscopy units. Publication History Article published online: 27 August 2026 © 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Private Limited A-13A, Graphix Tower 1, 6th floor, Sector 62, Noida 201309, Uttar Pradesh, India
Zitieren
APA
Sharma, Z. D. (2026). Single-Balloon Enteroscopy versus Double-Balloon Enteroscopy: Do We Really Need the Second Balloon?. Journal of Digestive Endoscopy, 17(S 01 S 01), S1-S138. https://doi.org/10.1055/s-0046-1828841
Vancouver
Sharma ZD. Single-Balloon Enteroscopy versus Double-Balloon Enteroscopy: Do We Really Need the Second Balloon?. Journal of Digestive Endoscopy. 2026;17(S 01 S 01):S1-S138. doi:10.1055/s-0046-1828841
BibTeX
@article{Sharma2026,
author = {Sharma, Zubin Dev},
title = {Single-Balloon Enteroscopy versus Double-Balloon Enteroscopy: Do We Really Need the Second Balloon?},
journal = {Journal of Digestive Endoscopy},
year = {2026},
volume = {17},
number = {S 01 S 01},
pages = {S1--S138},
doi = {10.1055/s-0046-1828841}
}
EUVIMED