EUVIMEDEUVIMED entdecken
Crossref

From Bedside to Electrodes: Reclassifying Myoclonus with Neurophysiology

Karandeep Kaur, Gagandeep Singh, Birinder Singh Paul

International Journal of Epilepsy · 01.08.2026 · 12 (S 01 S 01) · S3-S35

DOI: 10.1055/s-0046-1825890 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Epilepsy, erschienen am 01.08.2026. Verfasst von Karandeep Kaur und 2 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Clinical identification of myoclonus is often challenging, with potential misclassification due to overlap with other hyperkinetic movements. Neurophysiological techniques such as surface electromyography (EMG), somatosensory evoked potentials (SSEP), and Bereitschaft potential (BP) provide objective tools for confirmation and localization of myoclonus.

Objective

To evaluate the role of surface EMG in confirming myoclonus and to further classify electrophysiologically confirmed cases into cortical and subcortical subtypes using SSEP and BP.

Methods

In this prospective observational study, patients with clinically suspected myoclonus were enrolled and underwent detailed neurophysiological evaluation. Surface EMG was performed in all patients to assess jerk duration and morphology, enabling reclassification into myoclonic and nonmyoclonic groups. Patients with electrophysiologically confirmed myoclonus were further evaluated using SSEP and BP to determine cortical versus subcortical origin.

Results

A total of 10 patients with clinically suspected myoclonus were included. Based on surface EMG analysis, 4 (40%) patients were reclassified as nonmyoclonic due to jerk durations inconsistent with myoclonus. Among the remaining 6 patients with confirmed myoclonus, 4 (66.7%) demonstrated features of cortical myoclonus, evidenced by giant SSEPs and the presence of BP. The remaining 2 (33.3%) were classified as subcortical myoclonus based on absence of cortical electrophysiological correlates. Overall, neurophysiological evaluation led to a change in diagnosis in 40% of cases.

Conclusion

Surface EMG is a valuable tool in confirming true myoclonus and avoiding misdiagnosis. Advanced neurophysiological techniques such as SSEP and BP further aid in precise localization, with important diagnostic and therapeutic implications. A significant proportion of clinically suspected cases may be reclassified following objective evaluation, underscoring the importance of neurophysiology in movement disorder assessment. Publication History Article published online: 15 July 2026 © 2026. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Thieme Medical and Scientific Publishers Private Limited A-13A, Graphix Tower 1, 6th floor, Sector 62, Noida 201309, Uttar Pradesh, India

Zitieren

APA

Kaur, K., Singh, G., & Paul, B. S. (2026). From Bedside to Electrodes: Reclassifying Myoclonus with Neurophysiology. International Journal of Epilepsy, 12(S 01 S 01), S3-S35. https://doi.org/10.1055/s-0046-1825890

Vancouver

Kaur K, Singh G, Paul BS. From Bedside to Electrodes: Reclassifying Myoclonus with Neurophysiology. International Journal of Epilepsy. 2026;12(S 01 S 01):S3-S35. doi:10.1055/s-0046-1825890

BibTeX
@article{Kaur2026,
  author = {Kaur, Karandeep and Singh, Gagandeep and Paul, Birinder Singh},
  title = {From Bedside to Electrodes: Reclassifying Myoclonus with Neurophysiology},
  journal = {International Journal of Epilepsy},
  year = {2026},
  volume = {12},
  number = {S 01 S 01},
  pages = {S3--S35},
  doi = {10.1055/s-0046-1825890}
}
Kostenlos starten →