EUVIMEDEUVIMED entdecken
Crossref

Image Quality and Data Consistency of Deep Learning Accelerated Sequences for Spine MRI

S. J. Lee

Seminars in Musculoskeletal Radiology · 2026-06 · 30 (S 01) · S1-S22

DOI: 10.1055/s-0046-1824409 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Musculoskeletal Radiology, online erschienen am 02.06.2026. Verfasst von S. J. Lee.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose or Learning Objective: To validate the subjective image quality and data consistency of deep learning (DL)-accelerated T2-weighted turbo spin-echo (TSE) and Dixon sequences of the cervical spine compared with conventional T2-weighted Dixon (C-Dixon). Methods or Background: Three groups of 50 patients (a total of 150 patients) underwent sagittal C-Dixon, DL- accelerated T2- weighted Dixon (DL-Dixon), and DL- accelerated TSE T2-weighted imaging (DL-TSE), respectively. Acquisition parameters including scan time were compared; nonuniformity (NU) values were calculated. Two radiologists independently assessed each imaging method for subjective image quality and evaluated the presence of the pathologic lesions. Inter-reader agreements were estimated with weighted κ values. Results or Findings: Among all sequences, the DL-TSE showed the shortest acquisition time. The NU was lowest in DL-TSE. For both readers, the subjective image quality scores were higher in DL-accelerated sequences in all anatomic structures. The DL-TSE showed the highest motion artifact score (3.740.56, 3.70.65), whereas the DL-Dixon showed a similar or even lower score (3.20.9, 3.240.82) than the C-Dixon (3.20.73, 3.220.68). The degree of agreement was not changed by all sequences in disk herniation (almost perfect; range,: 0.801–0.854), facet arthropathy (substantial; range, 0.624–0.702), and neural foraminal stenosis (substantial; range, 0.645–0.760). However, in uncovertebral arthropathy, DL-TSE showed improved inter-reader agreement (almost perfect; value = 0.876) than other sequences (substantial; values = 0.758, 0.771). And in the central canal stenosis, C-Dixon and DL-Dixon showed higher agreement (almost perfect; values = 0.874, 0.825) than DL-TSE (substantial; value = 0.777). Conclusion: Deep learning accelerated sequences reduced acquisition time more than conventional sequences. Data consistency was maintained and even improved in some categories by DL-accelerated sequences that might propose the DL maintained data consistency through the reconstruction. The DL-accelerated sequences may be recommended for cervical spine magnetic resonance imaging, considering scan time, subjective image quality, and data consistency. In particular, DL-TSE is better than DL-Dixon images. Publication History Article published online: 02 June 2026 © 2026. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

Zitieren

APA

Lee, S. J. (2026). Image Quality and Data Consistency of Deep Learning Accelerated Sequences for Spine MRI. Seminars in Musculoskeletal Radiology, 30(S 01), S1-S22. https://doi.org/10.1055/s-0046-1824409

Vancouver

Lee SJ. Image Quality and Data Consistency of Deep Learning Accelerated Sequences for Spine MRI. Seminars in Musculoskeletal Radiology. 2026;30(S 01):S1-S22. doi:10.1055/s-0046-1824409

BibTeX
@article{Lee2026,
  author = {Lee, S. J.},
  title = {Image Quality and Data Consistency of Deep Learning Accelerated Sequences for Spine MRI},
  journal = {Seminars in Musculoskeletal Radiology},
  year = {2026},
  volume = {30},
  number = {S 01},
  pages = {S1--S22},
  doi = {10.1055/s-0046-1824409}
}
Kostenlos starten →