EUVIMEDEUVIMED entdecken
Crossref

Ultrasound-Guided Hydrodissection for Sciatic Neuropathy following Hip Arthroplasty

O. K. Nwawka, S. Benitez, R. Rahman, P. Sculco, S. Lee, T. Sculco

Seminars in Musculoskeletal Radiology · 2026-06 · 30 (S 01) · S1-S22

DOI: 10.1055/s-0046-1824375 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Seminars in Musculoskeletal Radiology, online erschienen am 02.06.2026. Verfasst von O. K. Nwawka und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose or Learning Objective: Sciatic neuropathy is a rare complication of total hip arthroplasty (THA). Although most instances resolve within the first 6 months, sciatic nerve distribution dysesthesias and motor deficiency can produce pronounced patient morbidity. A small subset of patients shows little to no longitudinal clinical or electrodiagnostic improvement despite absent or mild neuropathy on imaging. This case series presents outcomes of an ultrasound-guided perineural sciatic nerve hydrodissection for these patients with persistent sciatic neuropathy after THA. Methods or Background: This retrospective study received institutional review board approval. Between January 1, 2013, and April 1, 2025, a search of the radiology information system captured patients who had undergone ultrasound-guided perineural hydrodissection of the sciatic nerve following THA. These data were collected: patient demographics, date of surgery, date(s) of hydrodissection, pre-procedure symptoms (dysesthesia, weakness), and post-procedure response. The hydrodissections were performed by two fellowship-trained musculoskeletal radiologists, using 22G spinal needles and ultrasound guidance to administer epineural sterile saline. Results or Findings: A total of 13 patients (77% female) underwent sciatic nerve hydrodissection for persistent sciatic neuropathy following THA. The average age was 66.8 years. Twelve patients had a THA replacement; one patient had a hip resurfacing arthroplasty. The average interval between the date of surgery and the date of hydrodissection was 20.5 months (range, 4.75–60 months). Patients underwent an average of 3.3 hydrodissection procedures each (range, 1–12). Before hydrodissection, all patients (100%) reported sciatic nerve distribution dysesthesias, and 11 (85%) of patients had lower extremity motor weakness, predominantly foot drop. On follow-up, 85% of patients (11/13) reported post-procedure improvement in dysesthesia; 82% of patients (9/11) reported lessened motor weakness. Conclusion: Ultrasound-guided perineural hydrodissection of the sciatic nerve can improve dysesthesia and motor weakness in patients with post THA sciatic neuropathy. Patients may experience improvement in symptoms even after an interval of 5 years after surgery. Publication History Article published online: 02 June 2026 © 2026. Thieme. All rights reserved. Thieme Medical Publishers, Inc. 333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

Zitieren

APA

Nwawka, O. K., Benitez, S., Rahman, R., Sculco, P., Lee, S., & Sculco, T. (2026). Ultrasound-Guided Hydrodissection for Sciatic Neuropathy following Hip Arthroplasty. Seminars in Musculoskeletal Radiology, 30(S 01), S1-S22. https://doi.org/10.1055/s-0046-1824375

Vancouver

Nwawka OK, Benitez S, Rahman R, Sculco P, Lee S, Sculco T. Ultrasound-Guided Hydrodissection for Sciatic Neuropathy following Hip Arthroplasty. Seminars in Musculoskeletal Radiology. 2026;30(S 01):S1-S22. doi:10.1055/s-0046-1824375

BibTeX
@article{Nwawka2026,
  author = {Nwawka, O. K. and Benitez, S. and Rahman, R. and Sculco, P. and Lee, S. and Sculco, T.},
  title = {Ultrasound-Guided Hydrodissection for Sciatic Neuropathy following Hip Arthroplasty},
  journal = {Seminars in Musculoskeletal Radiology},
  year = {2026},
  volume = {30},
  number = {S 01},
  pages = {S1--S22},
  doi = {10.1055/s-0046-1824375}
}
Kostenlos starten →