Environmental and clinical safety of reusing polyp traps in colonoscopy: a prospective multicenter study
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S997-S998
DOI: 10.1055/s-0046-1822927 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von P Pedregal Pascual und 35 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
The polyp trap, designed for single use, is one of the many disposable items generated in an endoscopy unit. No studies have evaluated the safety or impact of its reuse. The aim of this study was to evaluate whether the reuse of polyp traps during colonoscopy is safe and efficient. Our hypothesis was that reusing polyp traps is non-inferior to discarding them with respect to infectious complications, while also assessing potential benefits in cost and environmental impact.
Methods
We conducted a prospective, multicenter, observational non-inferiority study including patients undergoing colonoscopy with polyp trap use between February 2025 and March 2026. Patients were assigned to the Discard Group (DG) or a Reuse Group (RG) according to the usual practice of each participating Center. Data collection included demographics, adverse events (infections, fever, delayed bleeding, perforation), pathology findings, and the number and types of polyp traps used. The primary endpoint was the rate of post-procedure related infection, with a non-inferiority margin (δ) of 0.4%. Secondary outcomes included discordance between endoscopic and pathology findings, device consumption, associated costs, and CO₂-equivalent emissions.
Results
A total of 3194 patients were included (1697 in DG; 1497 in RG), 57.2% male, with a mean age of 64±11 years and no baseline differences between groups. Delayed bleeding occurred in 62 patients (2%) and perforation in 3 (
Zitieren
APA
Pascual, P. P., Ros, O., Gariz, A. R., Boadas, J., Cornet, M., Galter, S., Romito, R., Guarner, E., Nodal, I. B., Artero, A., Loras, C., Bautista, M., Larrea, D., Lorenzo-Zúñiga, V., García, S., González, R. M., Colan-Hernandez, J., Lira-Aguilar, A., Grau-Manrubia, G., …, & Guarner-Argente, C. (2026). Environmental and clinical safety of reusing polyp traps in colonoscopy: a prospective multicenter study. Endoscopy, 58(S 03 S 03), S997-S998. https://doi.org/10.1055/s-0046-1822927
Vancouver
Pascual PP, Ros O, Gariz AR, Boadas J, Cornet M, Galter S, et al. Environmental and clinical safety of reusing polyp traps in colonoscopy: a prospective multicenter study. Endoscopy. 2026;58(S 03 S 03):S997-S998. doi:10.1055/s-0046-1822927
BibTeX
@article{Pascual2026,
author = {Pascual, P Pedregal and Ros, O and Gariz, A Ripoll and Boadas, J and Cornet, M and Galter, S and Romito, R and Guarner, E and Nodal, I Blanco and Artero, A and Loras, C and Bautista, M and Larrea, D and Lorenzo-Zúñiga, V and García, S and González, R Muñoz and Colan-Hernandez, J and Lira-Aguilar, A and Grau-Manrubia, G and Marti, G Espin and Gálvez, M and Olivé, M and Sanahuja, C and Danalachi, M and López, I and Orra, N and Serena, S Navajas and Soriano, A and Roig-Ramos, C and Abalos, J Gordillo and Romero-Mascarell, C and Torrella, L Escude and Martin, M Concepcion and Pulgar, M Murzi and Oliva, C Gomez and Guarner-Argente, C},
title = {Environmental and clinical safety of reusing polyp traps in colonoscopy: a prospective multicenter study},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S997--S998},
doi = {10.1055/s-0046-1822927}
}
EUVIMED