Clip artefact after duodenal endoscopic mucosal resection: prevalence and management
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S812
DOI: 10.1055/s-0046-1822249 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von B Lam und 10 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Large (≥15 mm) duodenal adenomas (DAs) are effectively managed by endoscopic mucosal resection (EMR). Prophylactic clip closure is frequently used to prevent complications. Unlike the colon, both residual or recurrent adenoma (RRA) and clip artefact exhibit a villiform pattern in the duodenum, complicating endoscopic interpretation. The prevalence and clinical impact of duodenal clip artefact (DCA) remain undefined.
Methods
Consecutive patients undergoing duodenal EMR between January 2016 and August 2024 at a tertiary center were prospectively enrolled. At first surveillance endoscopy (6 months), post-EMR scars were classified as: type 1 (bland), type 2 (nodular), or type 3 (residual clips with nodularity). Types 2/3 were defined as DCA and resected by cold-snare polypectomy. The primary outcome was DCA prevalence, secondary outcomes were diagnostic accuracy and procedural safety.
Results
Clips were used in 33/255 (15%) resections. Among 32 patients with follow-up, scars were type 1 (n=13), type 2 (n=15), and type 3 (n=4), yielding a DCA prevalence of 59.4%. RRA was confirmed histologically in 16% (3/19) but predicted endoscopically in only 33.3% (n=1). No adverse events occurred following cold-snare excision.
Conclusions
Duodenal clip artefact develops in 60% of clipped EMR sites and frequently mimics recurrence. Cold-snare excision is safe, provides definitive diagnosis, and simplifies subsequent surveillance. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Lam, B., Gupta, S., Mandarino, F. V., Kerrison, C., Kim, J., Hasib, A., Eitan, M., Kim, Y. S., Lee, E. T., Burgess, N., & J, B. M. (2026). Clip artefact after duodenal endoscopic mucosal resection: prevalence and management. Endoscopy, 58(S 03 S 03), S812. https://doi.org/10.1055/s-0046-1822249
Vancouver
Lam B, Gupta S, Mandarino FV, Kerrison C, Kim J, Hasib A, et al. Clip artefact after duodenal endoscopic mucosal resection: prevalence and management. Endoscopy. 2026;58(S 03 S 03):S812. doi:10.1055/s-0046-1822249
BibTeX
@article{Lam2026,
author = {Lam, B and Gupta, S and Mandarino, F V and Kerrison, C and Kim, J and Hasib, A and Eitan, M and Kim, Y S and Lee, EY T and Burgess, N and J, B Michael},
title = {Clip artefact after duodenal endoscopic mucosal resection: prevalence and management},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S812},
doi = {10.1055/s-0046-1822249}
}
EUVIMED