EUVIMEDEUVIMED entdecken
Crossref

Performance of TOP100 Software in Detecting Key Small Bowel Findings at Capsule Endoscopy

A Devanand, M Moore, FW D Tai, M Hale, C Bentley, V Thurston, A Healy, M McAlindon, N Nandi, R Sidhu

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S779

DOI: 10.1055/s-0046-1822177 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von A Devanand und 9 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Capsule endoscopy (CE) is a non-invasive diagnostic modality that has become a valuable tool for evaluating small bowel (SB) pathology. Despite its clinical value, it is limited by the time required for complete video interpretation and the associated reader fatigue. Studies have shown that accuracy drops even in the hand of experts after just one video. Artificial intelligence software has been developed to assist the reporting process. TOP100 is an integrated software that selects 100 images most likely to contain abnormalities (1). The aim of this study was to assess the overall diagnostic performance of TOP100 for specific SB findings in real-life clinical practice, by comparison with the standard reader together with its performance across different clinical indications [ 1 ].

Methods

A retrospective single-centre cohort study was conducted at our tertiary referral centre. We included all consecutive patients who underwent CE using the PillCam SB3 system between January 2024 to August 2025. Data collected included: baseline demographics, comorbidities, previous endoscopy and laboratory findings, indications for CE, adequacy of bowel preparation. CE findings were compared between the standard reader (SR) and a second reader using the TOP100 images, who was blinded to the original report. All CE readers had read>500 CE in their lifetime. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NVP) of TOP100 were compared to the SR (gold standard) for each type of CE finding (inflammatory, bleeding etc). A sub-analysis of diagnostic accuracy was also performed based on the CE indication.

Results

A total of 812 patients were included, however 5 were excluded from the analysis, with 3 unable to swallow the capsule and 2 lacking available Top100 readings. The final analysis comprised of 807 patients (57% female, median age 53 years, IQR 34–65). The most common indications were suspected or known inflammatory bowel disease (IBD) (50%), and iron-deficiency anaemia (24%). In 88% of patients the bowel prep was adequate and 90% had a complete examination. Median SB transit time was 3h51mins (2h46 – 4h50m). The diagnostic yield of findings at CE was significantly higher by SR compared to TOP100 (40% vs 29%, p

Zitieren

APA

Devanand, A., Moore, M., Tai, F. D., Hale, M., Bentley, C., Thurston, V., Healy, A., McAlindon, M., Nandi, N., & Sidhu, R. (2026). Performance of TOP100 Software in Detecting Key Small Bowel Findings at Capsule Endoscopy. Endoscopy, 58(S 03 S 03), S779. https://doi.org/10.1055/s-0046-1822177

Vancouver

Devanand A, Moore M, Tai FD, Hale M, Bentley C, Thurston V, et al. Performance of TOP100 Software in Detecting Key Small Bowel Findings at Capsule Endoscopy. Endoscopy. 2026;58(S 03 S 03):S779. doi:10.1055/s-0046-1822177

BibTeX
@article{Devanand2026,
  author = {Devanand, A and Moore, M and Tai, FW D and Hale, M and Bentley, C and Thurston, V and Healy, A and McAlindon, M and Nandi, N and Sidhu, R},
  title = {Performance of TOP100 Software in Detecting Key Small Bowel Findings at Capsule Endoscopy},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S779},
  doi = {10.1055/s-0046-1822177}
}
Kostenlos starten →