Artificial intelligence as the new reference standard for accurate polyp size measurement
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S738-S739
DOI: 10.1055/s-0046-1822090 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von D Gerritsen und 4 weiteren Autor:innen.
Abstract (Originalsprache)
Problem to solve The best reference standard for size measurement after polypectomy so far is caliper-based size measurement. However, this is time-consuming and may be inaccurate because of polyp fragmentation, distortion, or other deformations due to piecemeal resection, retrieval-related damage, inappropriate compression, or folding. This underscores the need for novel measurement tools. Innovation MAGENTIQ-COLO (MAGENTIQ EYE, Haifa, Israel) is an AI-based system that offers real-time polyp size assessment during colonoscopy or retrospective video evaluation. A video-based validation study was performed to assess the accuracy of this AI system compared to caliper-based size measurement of colorectal polyps. Results A total of 77 polyps was measured in 55 patients (male sex, n (%): 29 (52.7%), age median, interquartile range (IQR): 67 (13)). Colonoscopy indications were surveillance in 38 (69.1%), screening in 7 (12.7%), and diagnostic in 10 patients (18.2%). Of the 77 polyps, the majority of polyps were adenomas (n=52; 67.5%). Polyps were equally distributed through the colon. The AI-based system correctly identified size in 37/46 polyps (80.4%) as≤5 mm and 5/6 polyps (83.3%) as≥10 mm ([ Table 1 ]). The system had a mean accuracy of 0.80 for≤5 mm polyps (n=46), 0.88 for 6-9 mm polyps (n=25), and 0.83 for≥10 mm polyps (n=6), with a total mean accuracy of 0.84. Accounting for the skewed number of polyps per size category, the weighted accuracy was 0.83, with a weighted sensitivity and specificity of 0.83 and 0.92, respectively. The system reliably estimated polyp size, with a slightly higher accuracy for>5 mm polyps compared to≤5 mm polyps. From initial polyp detection to showing size, median latency was 5 frames (±0.17 seconds). Table 1 Confusion matrix of ground truth polyp size by caliper and predicted polyp size by the AI-based system AI system (≤5 mm) AI system (6-9 mm) AI system (≥10 mm) Caliper (≤5 mm) 37 9 0 Caliper (6-9 mm) 1 22 2 Caliper (≥10 mm) 0 1 5 Conclusions The novel AI-based system demonstrated a high accuracy compared to the reference standard of calipers, signifying that the AI system correctly identified most polyps within their true size categories with a low risk of size misclassification. Furthermore, colonoscopy time only slightly increased, allowing timely size assessment. This system could well replace the caliper as the reference standard for in-vivo size measurement of polyps during colonoscopy, but further prospective studies are needed. Acknowledgement: We express our gratitude to the MAGTENIQ-COLO study group for their contribution to drafting this abstract. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Gerritsen, D., Renteln, D. V., Koch, A. D., Rijckborst, V., & Siersema, P. D. (2026). Artificial intelligence as the new reference standard for accurate polyp size measurement. Endoscopy, 58(S 03 S 03), S738-S739. https://doi.org/10.1055/s-0046-1822090
Vancouver
Gerritsen D, Renteln DV, Koch AD, Rijckborst V, Siersema PD. Artificial intelligence as the new reference standard for accurate polyp size measurement. Endoscopy. 2026;58(S 03 S 03):S738-S739. doi:10.1055/s-0046-1822090
BibTeX
@article{Gerritsen2026,
author = {Gerritsen, D and Renteln, D Von and Koch, A D and Rijckborst, V and Siersema, P D},
title = {Artificial intelligence as the new reference standard for accurate polyp size measurement},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S738--S739},
doi = {10.1055/s-0046-1822090}
}
EUVIMED