Carbon and Financial Impact of reusing Bite Blocks in Upper Gastrointestinal Endoscopy
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S522
DOI: 10.1055/s-0046-1821610 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von G Marcellier und 10 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Over one million upper endoscopies are performed annually in France. Although no regulation mandates it, single-use (SU) bite blocks remain the standard practice. We evaluated the environmental benefit of switchint to reusable (RU) bite blocks for upper gastrointestinal endoscopy.
Methods
Reusable polyoxymethylene (POM) bite blocks (TEC-CARE, Chavelot, France) combined with rubber bands were tested. Preliminary tests consisted of subjecting the bite blocks to repeated steam sterilization cycles (134°C, 18 min) after real-life patient use. After confirming their integrity through successive sterilization cycles, a comparison was done between standard SU bite blocks (ALTON-Medical, China) and the reusable model under several scenarios (with or without reusing the rubber band, disinfection in automated endoscope reprocessors, or steam sterilization). A simplified life cycle assessment focusing exclusively on greenhouse gas emissions (kgCO₂e) was then performed using the CAREBONE tool developed by AP-HP (https://bit.ly/carebone).
Results
Twenty reusable bite blocks were used over two months. All tolerated at least ten sterilization cycles with no visible degradation impairing their use. However, the rubber bands did not withstand sterilization, requiring continued use of single-use bands due to the lack of suitable reusable alternatives. Several scenarios were compared, assuming ten uses per RU bite block: Single-use bite block+single-use band: 1.05 kgCO₂e Reusable bite block (sterilized)+single-use band: 1.25 kgCO₂e Reusable bite block (disinfected)+single-use band: 0.62 kgCO₂e Reusable bite block (disinfected)+reusable band (hypothetical due to lack of a readily available model): 0.12 kgCO₂e If reusable bite blocks with reusable bands were implemented nationwide (≈1 million oral procedures/year), emissions avoided would amount to 930 tCO₂e per year, equivalent to 260,000 cheeseburgers or to the carbon footprint of building 20 new detached houses (French Ecological Agency ADEME).
Conclusions
We demonstrated that POM reusable bite blocks withstand repeated sterilization Sterilizing reusable bite blocks combined with disposable bands does not provide an ecological advantage over single-use devices due to the environmental burden of sterilization. In contrast, disinfection in automated endoscope washer-disinfectors reduces CO₂ emissions by approximately 40%. These findings led to a change in practice in our department, with the adoption of reusable bite blocks (combined initially with disposable bands) disinfected together with the endoscope after each procedure. Acknowledgement: POM bite blocks were graciously manufactured and provided for freeby Tec-Care Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Marcellier, G., Moizard, M., Tan, D., Seytre, D., Gerardin, S., Maisoncelle, I. D., Lopez, B., Frelet, P., Camus, E., Rakotoharimanana, M., & Prat, F. (2026). Carbon and Financial Impact of reusing Bite Blocks in Upper Gastrointestinal Endoscopy. Endoscopy, 58(S 03 S 03), S522. https://doi.org/10.1055/s-0046-1821610
Vancouver
Marcellier G, Moizard M, Tan D, Seytre D, Gerardin S, Maisoncelle ID, et al. Carbon and Financial Impact of reusing Bite Blocks in Upper Gastrointestinal Endoscopy. Endoscopy. 2026;58(S 03 S 03):S522. doi:10.1055/s-0046-1821610
BibTeX
@article{Marcellier2026,
author = {Marcellier, G and Moizard, M and Tan, D and Seytre, D and Gerardin, S and Maisoncelle, I De and Lopez, B and Frelet, P and Camus, E and Rakotoharimanana, M and Prat, F},
title = {Carbon and Financial Impact of reusing Bite Blocks in Upper Gastrointestinal Endoscopy},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S522},
doi = {10.1055/s-0046-1821610}
}
EUVIMED