The effectiveness of a hemostatic gel (3D-Matrix 621-062) in the prevention of delayed bleeding after EMR of non-ampullary duodenal lesions
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S372
DOI: 10.1055/s-0046-1821289 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von S Arnaert und 6 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Duodenal endoscopic mucosal resection (EMR) has a high risk of bleeding. In a historical consecutive series of duodenal EMR in our hospital we found in 13/34 cases (38%) active bleeding or high-risk stigma of bleeding (visible vessel after removal of a blood clot) on next day gastroscopy (EGD). Prophylactic application of a haemostatic gel (3D-Matrix 621-062) to the EMR field may be an easy way to prevent delayed bleeding 1 . The aim of the study was to assess the efficacy of 3D-Matrix 621-062 in reducing delayed bleeding following duodenal EMR.
Methods
We conducted a single-arm, multicenter observational trial of patients undergoing hot-snare EMR of duodenal non-ampullary lesions of≥10 mm. Following EMR, 3D-Matrix 621-062 was applied directly to the EMR defect. The next day, an EGD was performed to detect active bleeding or high-risk stigma of bleeding (visible vessel after removal of a blood clot). We hypothesized a 50% decrease in bleeding stigma from 38 to 19%; sample size was calculated for power of 90% and Alpha of 0.05. The number of subjects to be enrolled was 59 patients.
Results
From October 2020 until August 2025, 59 patients from 5 different centers were included. Mean lesion size was 21.73 mm. 3D-Matrix 621-062 application was feasible in all patients. On EGD the next day, active bleeding (10 patients; 17%) or visible vessel after removal of a blood clot (6 patients; 10%) was seen in 16 patients (27%) (Fisher’s exact P=0.35, NS). During hospital stay, melena and hematemesis were observed in respectively 4 (7%) and 1 patient (2%). Hypotension was not observed. Treatment by placement of a hemoclip was performed in only 9 patients (15%) and relevant blood loss of≥1 g/dL was seen in 3 patients (5%).
Conclusions
Application of 3D-Matrix 621-062 following duodenal EMR did not significantly decrease the rate of bleeding or bleeding stigmata on next day EGD in comparison to a historical cohort. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Arnaert, S., Dewint, P., Wulf, D. D., Bouhadan, S., Baldaque-Silva, F., Bisschops, R., & Demedts, I. (2026). The effectiveness of a hemostatic gel (3D-Matrix 621-062) in the prevention of delayed bleeding after EMR of non-ampullary duodenal lesions. Endoscopy, 58(S 03 S 03), S372. https://doi.org/10.1055/s-0046-1821289
Vancouver
Arnaert S, Dewint P, Wulf DD, Bouhadan S, Baldaque-Silva F, Bisschops R, et al. The effectiveness of a hemostatic gel (3D-Matrix 621-062) in the prevention of delayed bleeding after EMR of non-ampullary duodenal lesions. Endoscopy. 2026;58(S 03 S 03):S372. doi:10.1055/s-0046-1821289
BibTeX
@article{Arnaert2026,
author = {Arnaert, S and Dewint, P and Wulf, D De and Bouhadan, S and Baldaque-Silva, F and Bisschops, R and Demedts, I},
title = {The effectiveness of a hemostatic gel (3D-Matrix 621-062) in the prevention of delayed bleeding after EMR of non-ampullary duodenal lesions},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S372},
doi = {10.1055/s-0046-1821289}
}
EUVIMED