Clinical outcomes of a novel tapered-and-flared fully covered self-expandable metal stent for malignant distal biliary obstruction: a multicenter retrospective study
Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S214-S215
DOI: 10.1055/s-0046-1820992 ↗Kurz gefasst
Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von M Kobayashi und 5 weiteren Autor:innen.
Abstract (Originalsprache)
Aims
Conventional fully covered self-expandable metal stents (FCSEMS) for malignant distal biliary obstruction (MDBO) are typically cylindrical in shape. Recently, a newly designed tapered-and-flared FCSEMS (K-papilla stent; SB Kawasumi Co., Ltd., Tokyo, Japan) has become available. This stent features a tapered waist toward the distal end and a large distal flare. Its design is expected to reduce stent migration and sludge formation. This multicenter retrospective study evaluated the clinical outcomes of this novel stent.
Methods
Forty patients (median age: 76 years; 19 males and 21 females) who underwent placement of a 10-mm K-papilla stent for unresectable MDBO between May 2023 and July 2024 at five institutions in Japan were retrospectively analyzed.
Results
The underlying diseases were pancreatic cancer in 32 patients, cholangiocarcinoma in 5, and others in 3. Reasons for unresectability were distant metastasis (n=20), locally advanced disease (n=9), and poor general condition or patient refusal (n=11). Twenty-seven patients received chemotherapy. The procedure was performed as primary drainage in 13 cases and as reintervention in 27. Pancreatic duct obstruction was present in 26 cases. Regarding the gallbladder, 3 patients had undergone cholecystectomy, 11 had cystic duct invasion, and 26 did not. The technical success rate was 100% (40/40). Stent lengths of 8, 7, and 6 cm were used in 16, 3, and 21 cases, respectively. The clinical success rate was 98% (39/40); one patient failed due to bleeding, which improved after replacement with a 12-mm FCSEMS. Early adverse events included mild pancreatitis (n=4), cholecystitis (n=1), and bleeding (n=1), all of which were resolved conservatively or endoscopically. Among the 39 patients with clinical success, recurrent biliary obstruction (RBO) occurred in 10 cases during a median observation period of 271 days. The median time to RBO (TRBO) was 539 days (95% CI: 389–NR). The non-RBO rates at 3, 6, and 12 months were 94% (33/35), 71% (20/28), and 61% (11/18), respectively. The causes of RBO were sludge impaction (n=6), overgrowth (n=2), and stent migration (n=2). In addition, three asymptomatic migrations were observed. Late adverse events other than RBO included non-obstructive cholangitis (n=5) and liver abscess (n=1), all managed conservatively without ERCP or drainage. The median overall survival was 252 days.
Conclusions
Placement of a tapered-and-flared FCSEMS for unresectable MDBO demonstrated favorable outcomes with a low rate of migration and acceptable safety profile. This novel stent may represent a useful option, warranting further prospective evaluation. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany
Zitieren
APA
Kobayashi, M., Murabayashi, T., Iwata, K., Iwasa, Y., Kawakami, Y., & Kawaguchi, S. (2026). Clinical outcomes of a novel tapered-and-flared fully covered self-expandable metal stent for malignant distal biliary obstruction: a multicenter retrospective study. Endoscopy, 58(S 03 S 03), S214-S215. https://doi.org/10.1055/s-0046-1820992
Vancouver
Kobayashi M, Murabayashi T, Iwata K, Iwasa Y, Kawakami Y, Kawaguchi S. Clinical outcomes of a novel tapered-and-flared fully covered self-expandable metal stent for malignant distal biliary obstruction: a multicenter retrospective study. Endoscopy. 2026;58(S 03 S 03):S214-S215. doi:10.1055/s-0046-1820992
BibTeX
@article{Kobayashi2026,
author = {Kobayashi, M and Murabayashi, T and Iwata, K and Iwasa, Y and Kawakami, Y and Kawaguchi, S},
title = {Clinical outcomes of a novel tapered-and-flared fully covered self-expandable metal stent for malignant distal biliary obstruction: a multicenter retrospective study},
journal = {Endoscopy},
year = {2026},
volume = {58},
number = {S 03 S 03},
pages = {S214--S215},
doi = {10.1055/s-0046-1820992}
}
EUVIMED