EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Accuracy and Safety of a Newly Designed Franseen-Tip Needle with Macroscopic On-Site Evaluation for Solid Lesions: A Multicenter Study

D Paduano, P Karagyozov, M Spadaccini, G franchellucci, D Ramai, A Panarese, A Facciorusso, F Auriemma, C Federica, M Fiacca, C Gentile, E Solida und 6 weitere

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S204-S205

DOI: 10.1055/s-0046-1820974 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von D Paduano und 17 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Macroscopic on-site evaluation (MOSE) has gained interest as a practical tool for assessing tissue adequacy during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB). Recently, a new Franseen FNB needle was developed for EUS-TA, the SonoTip TopGain from Medi-Globe. This study aimed to assess the diagnostic performance and safety of MOSE-guided EUS-FNB using the SonoTip TopGain FNB needle across high-volume international centers.

Methods

This retrospective, multicenter study included 95 patients from nine international referral centers who underwent EUS-FNB with MOSE between May 2024 and January 2025. Inclusion criteria comprised adults (>18 years) with predominantly solid lesions undergoing EUS-FNB using the SonoTip TopGain FNB needle (22G or 25G) and without concurrent ROSE. Data on demographics, lesion characteristics, procedural details, and final histopathologic outcomes were collected. Biopsy adequacy was determined by endosonographers based on the presence of visible cores on macroscopic inspection [ 1 ] [ 2 ] [ 3 ] [ 4 ] [ 5 ] [ 6 ] [ 7 ] [ 8 ] [ 9 ] [ 10 ] [ 11 ] [ 12 ] [ 13 ] [ 14 ] [ 15 ] [ 16 ] [ 17 ] [ 18 ] [ 19 ] [ 20 ].

Results

The mean patient age was 65.2±12.0 years, with 53 males (55.8%). Most lesions were pancreatic (67.4%), with a mean size of 31.5±16.9 mm. The slow-pull technique was predominantly used, with 92 procedures (96.8%) employing a 22G needle. MOSE identified visible cores in 92 cases (96.8%). Of the 95 specimens, 6 (6.3%) were inconclusive. Cytology confirmed all 75 malignant cases (100%) and 14 of 20 benign cases (70%). Diagnostic performance for MOSE-positive samples demonstrated a sensitivity of 100%, specificity of 50%, positive predictive value of 96.7%, negative predictive value of 100%, and overall accuracy of 96.7%. Adverse events were minimal (3.2%).

Conclusions

MOSE using the SonoTip TopGain FNB needle demonstrates high diagnostic accuracy and excellent sensitivity for detecting malignancy, with a favorable safety profile. These findings support its utility as a reliable tool for real-time adequacy assessment in clinical practice. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

Paduano, D., Karagyozov, P., Spadaccini, M., franchellucci, G., Ramai, D., Panarese, A., Facciorusso, A., Auriemma, F., Federica, C., Fiacca, M., Gentile, C., Solida, E., Lehibi, A. A., Aljahdli, E., Almuhaidb, A., Alfadda, A., Repici, A., & Benedetto, M. (2026). Diagnostic Accuracy and Safety of a Newly Designed Franseen-Tip Needle with Macroscopic On-Site Evaluation for Solid Lesions: A Multicenter Study. Endoscopy, 58(S 03 S 03), S204-S205. https://doi.org/10.1055/s-0046-1820974

Vancouver

Paduano D, Karagyozov P, Spadaccini M, franchellucci G, Ramai D, Panarese A, et al. Diagnostic Accuracy and Safety of a Newly Designed Franseen-Tip Needle with Macroscopic On-Site Evaluation for Solid Lesions: A Multicenter Study. Endoscopy. 2026;58(S 03 S 03):S204-S205. doi:10.1055/s-0046-1820974

BibTeX
@article{Paduano2026,
  author = {Paduano, D and Karagyozov, P and Spadaccini, M and franchellucci, G and Ramai, D and Panarese, A and Facciorusso, A and Auriemma, F and Federica, C and Fiacca, M and Gentile, C and Solida, E and Lehibi, A Al and Aljahdli, E and Almuhaidb, A and Alfadda, A and Repici, A and Benedetto, M},
  title = {Diagnostic Accuracy and Safety of a Newly Designed Franseen-Tip Needle with Macroscopic On-Site Evaluation for Solid Lesions: A Multicenter Study},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S204--S205},
  doi = {10.1055/s-0046-1820974}
}
Kostenlos starten →