EUVIMEDEUVIMED entdecken
Crossref

Comparative efficacy and safety of Hot Axios vs. Hot Spaxus LAMS for EUS-guided gallbladder drainage in malignant distal obstruction: A multicenter retrospective propensity-matched study

G franchellucci, M Spadaccini, A Fugazza, F Auriemma, D Paduano, F Calabrese, M Fiacca, E Solida, L Petronio, C Gallo, E Forti, S Stigliano und 26 weitere

Endoscopy · 01.06.2026 · 58 (S 03 S 03) · S92-S93

DOI: 10.1055/s-0046-1820786 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Endoscopy, erschienen am 01.06.2026. Verfasst von G franchellucci und 37 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

The introduction of Lumen-Apposing Metal Stents (LAMS) has significantly influenced clinical practice in biliary drainage. Several studies have confirmed the efficacy and safety of LAMS for EUS-guided gallbladder drainage (EUS-GBD) as a valid option for distal malignant obstruction with a patent cystic duct. While various LAMS are currently available, no direct comparison has been conducted between the two most widely used devices: the Hot Axios (Boston Scientific, USA) and the Hot Spaxus (Taewoong Medical, South Korea). This study aims to perform the first direct comparison of efficacy and safety between Hot Axios and Hot Spaxus stents in EUS-GBD for malignant distal obstruction Methods This is an international, multicenter, retrospective study conducted in 9 tertiary centers. Outcomes were compared using 1:1 propensity score matching. The primary outcomes were clinical success and safety. Technical success was defined as adequate LAMS placement confirmed by endoscopic and radiologic assessment. Clinical success was defined as a decrease in total bilirubin of at least 15% within 24 hours and decrease of>50% within 14 days after the procedure. Secondary outcomes included overall survival and Adverse Events (AEs). AEs were graded according to the AGREE classification, with Severe AEs (SAE) defined as>Grade II.

Results

We enrolled 154 patients across the participating centers. After 1:1 propensity score matching, 82 patients were selected (41 per group). Baseline characteristics were well-balanced. The proportion of female patients was 51.2% (21/41) in the Hot Axios group and 53.7% (22/41) in the Hot Spaxus group. The mean age was 70.30 years (SD: 14.41) in the Hot Axios group and 70.39 years (SD: 11.30) in the Hot Spaxus group (p=0.98).Regarding technical details, EUS-GBD was performed via the gastric route in 78.1% (32/41) of the Hot Axios group and 73.2% (30/41) of the Hot Spaxus group. In the Hot Spaxus group, 21 stents were 10x20 mm, while the other 20 were 8x20 mm. In the Hot Axios group, 20 out of 41 stents measured 10x10 mm. Global adverse events (AEs) were recorded in 14 patients: 19.5% (8/41) in the Hot Axios group compared to 14.6% (6/41) in the Hot Spaxus group (p=0.770). According to the AGREE classification, two AEs were classified as severe (SAE). Specifically, bleeding occurred in 3 patients (7.3%) in the Hot Axios group compared to 0 in the Hot Spaxus group (p=0.241). No perforations were recorded. Stent occlusion due to food impaction occurred in 5 cases in the Hot Axios group compared to 6 in the other group (p=0.981); all were successfully treated endoscopically with the placement of a coaxial plastic stent.Clinical success was achieved in 85.4% of patients in the Hot Axios group and 88.4% in the Hot Spaxus group (p=0.683). Median total bilirubin levels before the endoscopist treatment were procedure were 10.6 mg/dL (IQR: 4.2 -16.1) and 11.5 mg/dL (IQR 7.3- 15.4:) for the Hot Axios and Hot Spaxus groups, respectively. At 14 days, the median total bilirubin levels decreased to 2.90 mg/dL (IQR: 1.70–4.25) in the Hot Axios group and 2.55 mg/dL (IQR: 2.00–4.48) in the Hot Spaxus group (p=0.97).

Conclusions

The Hot Spaxus stent demonstrates lower bleeding rate and similar efficacy to the Hot Axios stent for EUS-GBD in distal malignant obstruction jaundice treatment. Further prospective evidences with larger sample sizes are needed to confirm these initial findings. Publication History Article published online: 05 June 2026 © 2026. European Society of Gastrointestinal Endoscopy. All rights reserved. Georg Thieme Verlag KG Oswald-Hesse-Straße 50, 70469 Stuttgart, Germany

Zitieren

APA

franchellucci, G., Spadaccini, M., Fugazza, A., Auriemma, F., Paduano, D., Calabrese, F., Fiacca, M., Solida, E., Petronio, L., Gallo, C., Forti, E., Stigliano, S., Matteo, F. M. D., Mutignani, M., Vargas-Madrigal, J., Teoh, A., Bertani, H., Santi, M., Lakhtakia, S., …, & Mangiavillano, B. (2026). Comparative efficacy and safety of Hot Axios vs. Hot Spaxus LAMS for EUS-guided gallbladder drainage in malignant distal obstruction: A multicenter retrospective propensity-matched study. Endoscopy, 58(S 03 S 03), S92-S93. https://doi.org/10.1055/s-0046-1820786

Vancouver

franchellucci G, Spadaccini M, Fugazza A, Auriemma F, Paduano D, Calabrese F, et al. Comparative efficacy and safety of Hot Axios vs. Hot Spaxus LAMS for EUS-guided gallbladder drainage in malignant distal obstruction: A multicenter retrospective propensity-matched study. Endoscopy. 2026;58(S 03 S 03):S92-S93. doi:10.1055/s-0046-1820786

BibTeX
@article{franchellucci2026,
  author = {franchellucci, G and Spadaccini, M and Fugazza, A and Auriemma, F and Paduano, D and Calabrese, F and Fiacca, M and Solida, E and Petronio, L and Gallo, C and Forti, E and Stigliano, S and Matteo, F M Di and Mutignani, M and Vargas-Madrigal, J and Teoh, A and Bertani, H and Santi, M and Lakhtakia, S and Colombo, M and Andreozzi, M and Ferraris, M and Shin, I S and Park, J W and Jong, H M and Sonthalia, N and Goenka, M K and Tewary, A and Galasso, D and Aljahdli, E and Lehibi, A Al and Alfadda, A and Almuhaidb, A and Alkhairi, R and Ammar, A and Hassan, C and Repici, A and Mangiavillano, B},
  title = {Comparative efficacy and safety of Hot Axios vs. Hot Spaxus LAMS for EUS-guided gallbladder drainage in malignant distal obstruction: A multicenter retrospective propensity-matched study},
  journal = {Endoscopy},
  year = {2026},
  volume = {58},
  number = {S 03 S 03},
  pages = {S92--S93},
  doi = {10.1055/s-0046-1820786}
}
Kostenlos starten →